Importing HYDX Network Data

HYDX network data can be imported from csv files to InfoWorks networks. In order to import the data, the following fields must be included in the CV files:

 

  CSV File
Knooppunt ItObject Verbinding Kunstwerk Profiel Oppervlak Debiet Verloop NWRW Meta
Mandatory Fields UNI_IDE ITO_IDE UNI_IDE UNI_IDE PRO_IDE UNI_IDE UNI_IDE VER_IDE AFV_IDE ALG_ATL
PUT_IDE KWA_RIO KN1_IDE KWK_TYP   AFV_DEF DEB_TYP VER_TYP AFV_BRG  
KNP_XCO KWA_CUN KN2_IDE     AFV_IDE   VER_VOL AFV_IFX  
KNP_YCO KWA_GRW VRB_TYP     AFV_OPP     AFV_IFN  
MVD_NIV STD_GRW             AFV_IFA  
MVD_SCH               AFV_IFH  
KNP_VRM                  
KNP_BOK                  
KNP_BRE                  
KNP_TYP                  
CMP_IDE                  
Warning

To ensure that any entry in the HYDX csv file, which is enclosed by double quotation marks (" "), is correctly imported, any semi colons (;) present within single field entries enclosed by double quotation marks will be interpreted as field separators rather than part of the field entry.

To import HYDX network data to an ICM InfoWorks network:

  1. Open the InfoWorks network to be updated.
  2. Select Import | Model | from HYDX network data from the Network menu, and a Windows File Open dialog is displayed.
  3. Enter the path to the folder which contains the csv files to be imported in the Folder box.
  4. Click OK to import the data.

    When the import process is complete, a log file, which contains any conversion errors or warnings, is displayed.

For details of the HYDX data imported and conversions made by the importer, see the HYDX Conversion Notes topic.

Importing Network Data

HYDX Conversion Notes