Synergi conversion notes

Synergi Water data is contained in a Microsoft Access Database file (.MDB).

This topic discusses how InfoWorks converts existing Synergi network components into an InfoWorks network and InfoWorks network objects. Some data is not imported at all, or is only partially imported. Some Synergi objects are imported as more complex InfoWorks objects, and additional data will be required to completely define these InfoWorks objects.

General Notes

Please Note

To import Synergi data, a minimum version of Synergi 4.3 is required (versions 4.3 to 4.7 are supported).

Due to differences between InfoWorks WS and Synergi data models, a number of adjustments are made during the import process:

Run Settings

The settings on the Schedule Hydraulic Run View are set to the following:

Run Schedule Value

Start date

Analysis Date from Synergi

Start time

00:00

End date/time

Start date/time + 1 day

Time step

Time Step Size from Synergi

Computational accuracy

1 l/s

Disconnected System Set to Checked
Simulation Options: Stop outflow from em pty reservoirs Set to YES
Simulation Options: Enforce Value/PST regulation tolerance Set to YES

Pipes

IWWS Data Field

Values imported from Synergi

From Node

Name of Pipe From Node

To Node

Name of Pipe To Node

Link Suffix

Suffix added by InfoWorks for each parallel pipe

Asset ID

Pipe Name from Synergi

Diameter

Pipe Diameter

For MN (Manning) conduits, Diameter = 4 x Hydraulic Radius

Length

Pipe Length

For HE pipes, the equivalent length of minor losses is added to the pipe length.

Friction Type

Set to:

  • CW for DW pipes and non-zero roughness.
  • DW for DW pipes with zero roughness and MN pipes.
  • HW for HW and HE pipes.

Darcy Weisbach

Set for DW pipes. For MN (Manning) conduits, the conduit is converted to a circular pipe with

diameter = 4 x hydraulic diameter

The Mannings roughness coefficient is converted to a Darcy Weisbach friction factor.

Roughness

Only set if roughness in Synergi is non-zero.

Hazen Williams

Set for HW pipes.

Notes

Element Description from Synergi.

Valves

IWWS Data Field

Values imported from Synergi

From Node

Name of Valve From Node

To Node

Name of ValveToNode

Link Suffix

Suffix added by InfoWorks for each parallel pipe

Asset ID

Valve name from Synergi.

Length

Set to default value by InfoWorks:

1.0m

Diameter

Valve or Regulator Diameter

Friction Type

Set to default value by InfoWorks:

DW

DW - f

Set to default value by InfoWorks:

0.015

Valve Diameter

Valve or Regulator Diameter

Loss Coeff. (Open)

Valve Coefficient

Valve Curve

Set by InfoWorks to:

  • GATE if Loss Coeff=0.0001 and the valve is fully open or fully closed
  • PLUG otherwise

Mode ID

(control data)

Set by InfoWorks to:

  • THV for Synergi VL valves
  • TCV for Synergi VV valves
  • PRV for Synergi VP valves if the control node is the To node
  • PSV for Synergi VP valves if the control node is the From node
  • FRV for Synergi VF valves.

Opening (%)

(control data)

Valve Tau is converted to opening.

Pressure

(control data)

Regulator pressure; set for VP valves.

Flow

(control data)

Regulator flow; set for VF valves.

Control Node

(control data)

Set for VP valves.

Regulation Precision

(control data)

Set to default value by InfoWorks:

0.1

Notes

Element description

Non-return valves

IWWS Data Field

Values imported from Synergi

From Node

Name of Valve From Node

To Node

Name of Valve To Node

Link Suffix

InfoWorks adds a suffix for each parallel link

Asset ID

Valve name from Synergi

Local Loss Coefficient

Valve Coefficient

Length

Set to default value by InfoWorks:

1.0m

Diameter

Valve Diameter

Friction Type

Set to default value by InfoWorks:

DW

DW - f

Set to default value by InfoWorks:

0.015

Non Return Valve Diameter

Valve Diameter

Notes

Valve Element Description

Float valves

Note that profiles are not imported. IWWS substitutes its own internal profile curve.

Valves on reservoir links are converted to float valves in InfoWorks to prevent reservoir overtopping.

IWWS Data Field

Values imported from Synergi

From Node

Element From Node name

To Node

Element To Node name

Link Suffix

InfoWorks adds a suffix for each parallel link

Asset ID

Valve name

Local Loss Coefficient

Coefficient

Length

Set to default value by InfoWorks:

1.0m

Diameter

Diameter

Friction Type

Set to default value by InfoWorks:

DW

DW - f

Set to default value by InfoWorks:

0.015

Valve Diameter

Diameter

Valve Curve

Set to default value by InfoWorks:

DefaultFLV

Regulation Type

Continuous if a profile is specified or if the regulating range (see below) is 0.

On/Off if no profile.

Opening (%)

Valve Tau is converted to opening.

Regulating range

Imported from Synergi.

Inlet level

Elevation of From Node.

Backfeed pipe

Set to default value by InfoWorks:

  • No for Synergi tank fill valves
  • Yes for other valves

Control Depth

(control data)

If a valve profile is specified in Synergi :

Top water level – first X value in valve profile

(X valves in Synergi specify the drop from the top of the reservoir).

If no profile is specified :

Top water level – bottom water level

Initially Open

(control data)

Open if initial position > 0.5.

Closed if initial position <= 0.5.

Notes

Element description

Nodes

IWWS Data Field

Values imported from Synergi

Node ID

Node Name

X

X coordinate for node

Y

Y coordinate for node

Elevation

Node Elevation

Notes

Node Description

Fixed heads

Nodes are imported as fixed head nodes if they have a known pressure and they are not a control node for a valve or a pumping station. If the fixed head nodes have demand in Synergi then the demands are not imported because fixed head nodes in InfoWorks cannot have demand.

IWWS Data Field

Values imported from Synergi

Node ID

Node Name

X

X coordinate for node

Y

Y coordinate for node

Elevation

Node Elevation

Constant Head

If head is fixed:

Node PressureorHGL value + Node Elevation

Head Profile

If head is variable:

  • Date-time set from Node Profile X value
  • Head values set from node profile Y value + Node Elevation

Notes

Node Description

Transfer nodes

Nodes are imported as transfer nodes if they have negative demand. If the transfer node has more than one demand category only the first category will be imported.

IWWS Data Field

Values imported from Synergi

Node ID

Node Name

X

X coordinate for node

Y

Y coordinate for node

Elevation

Node Elevation

Flow Factor

(control data)

Set to default value by InfoWorks: 1

Head Profile

(control data)

Date-time set from Node Profile X value

Head values set from node profile Y value

Notes

Node Description

Reservoirs

IWWS Data Field

Imported Values

Node ID

Name of Tank From Node

X

X coordinate of Tank From Node

Y

Y coordinate of Tank From Node

Elevation

Elevation at Tank From Node

Bottom Reservoir Level

Elevation of Tank From Node + Tank Bottom value.

Top Water Level

Elevation of Tank To Node.

Depth/Volume profile

Imported from Synergi Profile X and Y.

Depths below 0.20 m and volumes below 1.0 m3 are not imported.

Notes Tank element Description

Initial Depth

(control data)

TankLevel of Tank element

Pumps

IWWS Data Field

Values imported from Synergi

Pump ID

Imported from Synergi

Nominal Flow

Calculated by Infoworks:

Average flow from head-discharge profile.

Nominal Speed

Pump Rated Speed

Suction Diameter

Calculated by InfoWorks:

Nominal value based on a diameter calculated from the nominal flow and a velocity of 4 m/s.

Pressure Diameter

Calculated by InfoWorks:

Nominal value based on a diameter calculated from the nominal flow and a velocity of 4 m/s.

Q-H-P curve

Q set from Synergi profile X value

H set from Synergi profile Y value

P calculated by InfoWorks from Q and H, assuming a constant efficiency of 80%

Pump stations

IWWS Data Field

Values imported from Synergi

From Node

Name of element From Node

To Node

Name of element To Node

Link Suffix

InfoWorks adds a suffix for each parallel link

Asset ID

Pump name

Length

Set to default value by InfoWorks:

1.0m

Diameter

Set to default value by InfoWorks:

555 mm

Friction Type

Set to default value by InfoWorks:

DW

DW - f

Set to default value by InfoWorks:

0.015

Power Factor

Set to default value by InfoWorks:

0.9

PST Duty Head

First value from head-discharge profile or 0.0.

Electrical Mechanical Power Ratio

Set to default value by InfoWorks:

1.25

Voltage

Set to default value by InfoWorks:

LOW

Duty flow

Set to default value by InfoWorks:

99 l/s

Local Loss Coefficient

Set to default value by InfoWorks:

0.0

Tariff Name

Set to default value by InfoWorks:

M3

Mode Of Control

(control data)

If a control node is specified and the set pressure is specified, control mode is PROF,

Else if a time-speed profile is specified, control mode is PLAN,

Else if a control node is specified and a level, control mode is AUTO,

Else if a speed is specified, control mode is PLAN

Otherwise the Mode of Control is not set.

Target Deviation On

(control data)

Set to default value by InfoWorks:

-1.0m (for PROF pumps)

Target Deviation Off

(control data)

Set to default value by InfoWorks:

1.0m (for PROF pumps)

Target Pressure Depth

(control data)

Derived by InfoWorks from set pressure (for PROF pumps).

Control Node

(control data)

Pump ControlNodeId

Minimum speed

Minimum of rated speed, speed (if non-zero), and PumpMin (if non-zero)

Maximum speed

Maximum of rated speed, speed (if non-zero), and PumpMax (if non-zero)

Notes

Pump description


Importing Synergi Data

Import Synergi dialog