Associating and editing control items

The flow of water through a network can be regulated by the inclusion of controls. These are links such as valves and pumps. Some controls have a constant effect on the network; others, such as certain types of valves and pumps, may be regulated over a period of time to alter the pressure in the network. 

The controls themselves form part of the network. The operational aspects of modelling a water supply system are contained in the control data. This data describes the initial state of the water supply network at the start of a simulation and the policy for controlling the network during the simulation.

The control data and network are separate items within the master database. This means that several control data items can be associated with the same network to model variations in control policy; alternatively, the same control data can be associated with more than one network so physical changes in the network can be modelled with the same control policy.

Creating control data

A new, blank control data can be created at any time. Alternatively, control data can be imported into InfoWorks WS Pro.

To create new control data:

Control data can be edited by associating control data with a network, then adding and editing control information for the objects in the network.

Associating control data with a network

Adding a control

Adding a control is not an explicit action. If a control is associated with the network, the control properties will appear beneath the main properties when you open an object's property sheet.

Tip: Use the Properties tool to display an object's property sheet.

ClosedShow image

Control properties

Editing a control

Control data can be edited by associating control data with a network, then adding and editing control information for the objects in the associated network.

Alternatively, control data can be edited independently of the network in the Control grid.

The Control grid is displayed when the Window | Grid windows menu is selected and the New control window option is selected:

ClosedShow image

When you have finished making changes, you must commit the control data to the master database. It is not committed when you commit the associated network, unless done via the Commit changes to master database button on the File toolbar.

Removing a control

Control data can be deleted for a network object using a tool on the toolbar of the object properties sheet.

ClosedShow image

Exporting a control

Control data can be exported in an EPANET .INP file (in conjunction with a network) or to a CSV file.

To export control data:

Example : Changing pipe controls 

For modelling purposes you can close a pipe either permanently or for just part of the simulation without having to change the pipe to a valve.

This stage assumes that you have started InfoWorks WS Pro and that the Model Group window is open, showing the Newtown icon.

To close the pipes:

  1. Right-click the 'Newtown Network' icon and select Open. The network is displayed on the GeoPlan.
  2. Open the Newtown Base Control to associate it with the network.

    ClosedShow image

    Control Data

  3. Zoom in on K400342.K400353.1.

    ClosedShow image

  4. Using the Properties button, open the property sheet for this pipe.

    The associated control data is shown on the properties sheet.

  5. Close the pipe permanently:
    • In the Pipe Closed Profile section, click the Pipe Closed box to select it.

    ClosedShow image

    Closing the Pipe

For a more comprehensive example of how controls can be used in InfoWorks WS Pro, click here.

Back to main flowchart Back to main flowchart