Cascade Routing Model

In the Cascade Routing Model, flow is routed using a specified number of linear reservoirs in series; each reservoir has the same (user-defined) time constant.

For each storage reservoir, the storage constant, K, is used and calculated as follows:

 

First reservoir in series:

(1)

Second reservoir in series:

(2)

..final reservoir in series:

(3)

Where:

q1 is the runoff from the first reservoir

q2 is the runoff from the second reservoir

qn is the runoff from the last reservoir

t is time in seconds

I is the rainfall intensity

K is the storage constant

The linear cascade is implemented for each reservoir using a finite difference approximation.

The runoff routing model for a Runoff Surface is set in the Runoff Surface Grid Window of the Subcatchments Grid or in the Runoff Surface Property Sheet.

The easiest way to set up surfaces for subcatchment cascade routing is to create a single surface with the following runoff surface properties:

Runoff Surface Data Field

Value

Routing model Cascade

On a subcatchment using this runoff surface, ensure that the Subcatchment properties are set to:

Subcatchment Data Field

Value

Storage factor K A numerical constant

Runoff Routing Models

Runoff Surfaces