UND File Conversion - Pumps

Data in the [MOUSE_PUMPS] group of the UND file is imported into the InfoWorks ICM Pump table. This topic contains details on the conversion of MOUSE pumps information to InfoWorks ICM.

Pump Group - [MOUSE_PUMPS]

MOUSE

Description

InfoWorks ICM Data Field

PUMPID

Pump name

Asset ID

LOCATION

Node ID where pump is placed

US Node ID

FLOWTO

Node ID where flow is diverted to.

If FLOWTO is not specified the pump discharges out of the system.

DS Node ID

If FLOWTO is not specified, an outfall node is created downstream of the pump, named <us node id>_out.

TYPENO

Pump Type

TYPENO

Type

1

Screw (H - Q)

2

Differential Head (dH - Q)

Link Type

MOUSE Type

InfoWorks ICM Type

Screw (H - Q)

SCRPMP

Differential Head (dH - Q)

ROTPMP

DATASETID1

Data Set ID for Capacity Curve.

Curve is defined in the TABULAR DATA section.

A Head Discharge Table is created named using the pump primary key.

Values to be imported into the head array and discharge array in the Head Discharge Table are determined from curve data in the TABULAR DATA section and OFFSETLEVEL value.

See the Note on Import of MOUSE Pump Capacity Curves below.

OFFSETLEVEL

Offset applied to Capacity Curve

Used to determine values to be imported into the head array and discharge array in the Head Discharge Table associated with the pump.

See the Note on Import of MOUSE Pump Capacity Curves below.

STARTLEVEL

Start water level for pump

Switch on level

STOPLEVEL

Stop water level for pump

Switch off level

CONTROLTYPENO

Pump Control Type

CONTROLTYPENO

Type

1

No Control

2

RTC Control

3

Variable Speed Pump

Not imported as there is no equivalent in InfoWorks ICM.

ACCTIME

Acceleration time for pump

Delay

DECTIME

Deceleration time for pump

Not imported as there is no equivalent field in InfoWorks ICM.

Switch-off for all InfoWorks ICM pumps is immediate.

MINTIMEPUMPOFF

Minimum time the pump has to be off

Not imported as there is no equivalent field in InfoWorks ICM.

MINTIMEPUMPON

Minimum time the pump has to run

Not imported as there is no equivalent field in InfoWorks ICM.

MAXSTARTLEVEL

Maximum start water level for pump

Not imported as there is no equivalent field in InfoWorks ICM.

MINSTOPLEVEL

Minimum stop water level for pump

Not imported as there is no equivalent field in InfoWorks ICM.

DATASETID2

Acceleration curve.

Curve is defined in the TABULAR DATA section.

Not imported as there is no equivalent field in InfoWorks ICM.

WETWELLSETPOINT

Setpoint in Wet Well

Not imported as there is no equivalent field in InfoWorks ICM.

Note on Import of MOUSE pump Capacity Curves

The Capacity Curves for MOUSE pumps are defined in the TABULAR DATA section of the UND file and are used to calculate the values to be imported into the InfoWorks ICM Head Discharge Table.

Screw Pumps

MOUSE Screw Pumps are imported to InfoWorks ICM as pumps of Link Type SCRPMP.

MOUSE Screw Pumps require a capacity curve of type QH, where H is the absolute water level in the pump's wet well. The InfoWorks ICM Head Discharge curve for a Screw Pump describes the relationship between discharge and height above the pump Base Level.

The MOUSE QH Capacity Curve and Offset Level data are used to determine the InfoWorks ICM pump Base Level value and the values to be imported into the InfoWorks ICM Head Discharge Table:

Differential Head Pumps

MOUSE Differential Head pumps are imported to InfoWorks ICM as pumps of Link Type ROTPMP.

The MOUSE QdH Curve and Offset Level data are used to determine the values to be imported into the InfoWorks ICM Head Discharge Table: