Hydrant Flow Profile page
Allows you to view and edit Hydrant Flow Profiles for Basic Nodes and Hydrant Nodes. The Hydrant Flow Profile can only be edited on this page.
By default, if a Hydrant Flow Profile is applied to a node, any local demand, e.g. customer point demand, will be ignored. To apply local demand, check the Keep Local Demand option on the Node Control page of the node property sheet.
For more information on all node types, see Nodes. For general information on controls, see Control Data.
Hydrant Flow Grid
The Hydrant Flow grid defines the time varying profile for hydrant opening for the node. Each entry is the date and time of a change in the hydrant opening value.
By default no interpolation is used between data points. Each flow value entered in the grid is maintained until the next date / time entry, or until the end of the simulation. Check the Linear Profile box for linear interpolation to be used between data points.
The following options are available for extending the profile outside of the entered dates / times:
Data Field | Description | ||||||||
---|---|---|---|---|---|---|---|---|---|
Before First Point |
|
||||||||
After Last Point |
|
||||||||
Repeat Profile Checkbox |
Check the Repeat Profile box to repeat a profile (from 00:00 for the selected Repeat Period) for the duration of the simulation. IMPORTANT
When using the Repeat Profile option; if the defined profile spans over the selected Repeat Period, the profile will not be repeated. |
||||||||
Repeat Period |
Profile period which will be repeated throughout simulation, if the Repeat Profile box is checked. |