Importing from an InfoAsset Manager Collection Network

Data can be imported into a InfoWorks network from an InfoAsset Manager collection network within the database or within a Guest Database. You can control how data fields in the collection network are mapped onto the InfoWorks network fields. Default mappings are also available.

Note

Copying and pasting objects in InfoAsset Manager changes the internal unique ID of the object. If the InfoAsset Manager object ID is changed subsequent to import of the object, the update process will not work for that object. For example, copying and pasting objects to a new network and updating from the new network will not work if node names are changed subsequent to import of the original data.

To update a network with new data from an asset network:

  1. Open a GeoPlan Window of the InfoWorks network to be updated.
  2. Load a Background Network into the GeoPlan:
    • Drag in the Collection Network containing the data to be imported from the Explorer Window of the current database or from the Explorer Window of a Guest Database.
    • To select a previously committed version of the Collection Network, select Background Network from the Network menu to display the Background Network Dialog. Click the version button to display the commit history for the network, select the version required and click OK.
  3. Choose Import | Update from collection network from the Network menu. This displays the Choose Objects Dialog.
  4. Select the data source type options from the Choose Objects Dialog and click OK. The Update from Collection Network Dialog is displayed.
  5. Click the Advanced Options button to display the Import from Collection Network Dialog
    1. On the Update Page, choose whether to import flags from the collection network, or to set your own default flag on the imported data. You can also limit updates to only affect data that has a specific flag. See the Import Flags Rules section below for details on rules used for copying flags when the Import Flags option is selected.
    2. Tip

      It is recommended that you do not import flags from the InfoAsset Manager network, but allow the updater to set the #A (asset) flag on fields that are modified. Subsequent updates can then be set to allow modification of fields with the #A flag only. This allows the modeller to control which fields should be updated in future by changing the flag.

    3. On the Mappings Page, set how various fields from the collection network translate into valid network values. Also choose how to deal with unrecognised values
  6. Click OK to continue.

InfoWorks ICM will now import the data from the currently loaded version of the collection network and update the current network. InfoWorks ICM finally displays a log of the update process.

Import Flags Rules

When using the Import Flags option when updating an InfoWorks network from a collection network, the InfoWorks network flags are set according to the following rules:

Notes on importing network objects from InfoAsset Manager data

The table below includes details of the import of InfoAsset Manager network objects to InfoWorks network objects:

InfoAsset Manager Object Type Import Details
Assets (Nodes)

InfoAsset Manager Object

InfoWorks ICM Object

Node

Node

Node type is determined by the settings in the Mappings tab of the Import from Collection Network Dialog.

Connection Node Node of Node type Break
Outlet Node of Node type Outfall
Storage Area Node of Node type Storage
Assets (Links)

InfoAsset Manager Object

InfoWorks ICM Object

Pipe Conduit
Connection Pipe Not imported
Channel River Reach
Flume Flume
Orifice Orifice
Screen Screen
Pump Pump
Siphon Siphon
Sluice Sluice
User Ancillary Not imported
Valve Flap Valve
Vortex User Control of Link type Vortex
Weir Weir
Assets (Areas)

There is only one asset area type that is imported: the InfoAsset Manager Storage Area object is imported as an InfoWorks network Node of Node type Storage.

Assets (Points) InfoAsset Manager asset point objects are not imported
Line InfoAsset Manager line objects are not imported.
Zones InfoAsset Managerzone objects are not imported
Surveys There is only one survey type that is imported: the InfoAsset Manager Cross Section Survey object is imported as an InfoWorks network Cross Section Line.
Repairs InfoAsset Manager repair objects are not imported
Incident InfoAsset Manager incident objects are not imported.

 

InfoAsset Manager Asset

InfoWorks ICM Object

Pipe Conduit
Connection Pipe Not imported
Node

Node

Node type is determined by the settings in the Mappings tab of the Import from Collection Network Dialog.

Connection Node Node of Node type Break
Outlet Node Node of Node type Outfall
Storage Area Node of Node type Storage
Flume Flume
Orifice Orifice
Screen Screen
Pump Pump
Siphon Siphon
Sluice Sluice
Valve Flap Valve
Vortex User Control of Link type Vortex
Weir Weir

Notes on updating InfoWorks networks from InfoAsset Manager data

The table below includes details of some special update scenario cases:

Case

Action carried out in Collection Network

InfoWorks Network Update from Collection Network

Merged Pipes

-

Any areas of theInfoWorks network that have been merged will not be updated.

Pruned Objects

-

Any areas of the InfoWorks network that have been pruned will not be updated.

Renamed Objects US Node renamed

Node and downstream link renamed

Renamed Objects DS Node renamed Node renamed. DS Node ID field of upstream pipe updated.
Lateral Creation

Lateral nodes and links created

The pipe to which the lateral is connected (in the asset network) is split in the InfoWorks network creating a new pipe downstream of the lateral.
Lateral Deletion

Lateral nodes and links deleted

Lateral nodes and links deleted in the asset network are deleted from the InfoWorks network. The pipes that were connected to the lateral node are joined and the properties from the pipe upstream of the lateral are used.
Pipe Splitting

Pipe split downstream from a lateral

A new pipe is created downstream from the lateral.

Closed 

Pipe Splitting

Pipe split upstream from a lateral

A new pipe is created between the inserted node and the lateral. The new pipe and the pipe downstream from the lateral will be updated with the properties of the newly created pipe in the asset network.

Closed 

Merging

Pruning

GeoPlan Window