E0000
|
Not found in Network
Info
|
Object type. Object name.
|
Cause
|
An object to be used in the simulation cannot be found in the network. This message may be displayed if a Selection List has been chosen in the Schedule Hydraulic Run View defining a subset of the network that does not include the identified object.
|
Advice
|
Check that the correct selection list has been chosen in the Schedule Hydraulic Run View
|
|
|
E0001
|
Cannot run BalanceNet simulations, because Cost Management optimisation has been selected in the options dialog OR You are licensed to use BalanceNet runs and you have selected BalanceNet runs in the options dialog, but you are using the slower old-style Cost Management Optimiser.
Info
|
No additional information
|
Cause
|
Applicable to Cost Management Simulations and BalanceNet Simulations.
The optimisation types (Cost management or BalanceNet) specified in the Schedule Hydraulic Run View and the BalanceNet page of the Options dialog do not match.
|
Advice
|
Check that the optimisation type is the same in both dialogs.
|
|
|
E0015
|
This pump type has no Q-H-P entries
Info
|
Pump name
|
Cause
|
Flow, Head and Power characteristics have not been entered in the pump curve grid.
|
Advice
|
Enter pump characteristics into the pump curve grid.
|
|
|
E0018
|
Reservoir depth-volume table empty
Info
|
Reservoir name
|
Cause
|
Depth-volume grid has not been filled in on the Reservoir Parameters Page
|
Advice
|
Enter reservoir depth-volume relationship into the grid on Reservoir Parameters Page
|
|
|
E0019
|
There must be at least one pump
Info
|
Pumping Station name
|
Cause
|
There are no pumps assigned to the pumping station on the Pump Data Page
|
Advice
|
Select pumps to be assigned to pumping station from pull down menu on Pump Data Page and fill in data fields
|
|
|
E0029
|
Pump curve id (<index>) pump must have a duty flow less than 0 for a turbine
Info
|
Pumping Station name
|
Cause
|
The Turbine option on the Pumping Station Parameters Page has been checked, but the Duty Flow specified on the Pump Data page is greater than or equal to zero.
|
Advice
|
Set Duty Flow on the Pump Data page to a value less than zero.
|
|
|
E0030
|
Pump curve id (<index>) pump must have a speed that must be less than 0 for a turbine
Info
|
Pumping Station name
|
Cause
|
The Turbine option on the Pumping Station Parameters Page has been checked, but the Maximum Speed specified on the Pump Data page is greater than or equal to zero.
|
Advice
|
Set Maximum Speed on the Pump Data page to a value less than zero.
|
|
|
E0031
|
Demand category <demand category
name> not recognised
Info
|
Node name to which demand category has been assigned. Name of demand category.
|
Cause
|
The name of the demand category on the Node Demand Page does not exist in the Demand Diagram being used to carry out the simulation
|
Advice
|
Check that the correct Demand Diagram has been selected in the Run Scheduler. Check that the correct demand category has been assigned to node.
|
|
|
E0031
|
Demand category <demand category
name> not aligned with Category
Type
Info
|
Node name to which customer point with incorrect Category Type has been assigned
|
Cause
|
The Category Type of the Demand (User) Category assigned to a customer point, does not match the Category Type of the Demand Category in the Demand Diagram being validated.
|
Advice
|
For the customer points allocated to the reported node:
- Check that the correct Demand Category has been assigned
- Check that the correct Category Type has been assigned
|
|
|
E0034
|
Minimum/Maximum speed (<index>) Value is out of range (50 rpm to 5000 rpm)
Info
|
Pump station ID
|
Cause
|
The value in the Maximum Speed or Minimum Speed field of the pump curve identified is not within the recommended range of 50 rpm to 5000 rpm.
|
Advice
|
Review the Maximum Speed and Minimum Speed field values for the pump curve.
|
|
|
E0040
|
The network must have at least one
reservoir or fixed head object
Info
|
None
|
Cause
|
There must be at least one reservoir node or fixed head node in the network for the simulation to run
|
Advice
|
Check network boundary conditions have been set up
|
|
|
E0041
|
Old-style hydrant with more than
one connection
Info
|
Node name
|
Cause
|
A basic node with hydrant flow controls is connected to more than one link
|
Advice
|
Change the node type to a Hydrant node.
Create a dummy node connected to the network by one link to apply hydrant flow to a basic node.
|
|
|
E0112
|
Negative factor for area <area
code>
Info
|
Area code
|
Cause
|
The demand scaling ratio for the area indicated in the error message is negative
|
Advice
|
Check demand scaling
|
|
|
E0118
|
Tariff Label <tariff name>
not recognised
Info
|
Pump station name to which tariff has been assigned. Name of tariff
|
Cause
|
The name of the tariff assigned to the Pumping Station on the Pumping Station Parameters Page / Pump Station Grid does not exist in the Electricity Tariff file being used to carry out the simulation or the tariff data is incomplete.
|
Advice
|
Check that the correct Electricity Tariff file has been selected in the Run Scheduler. Check that the correct electricity tariff has been assigned to pumping station.
|
|
|
E0130
|
Tariff incomplete
Info
|
Tariff Label in Electricity Tariff being used in simulation
|
Cause
|
The data for the tariff indicated in the error message is incomplete.
|
Advice
|
Check that the correct Electricity Tariff file has been selected in the Run Scheduler. Complete data entry for electricity tariff.
|
|
|
E0203
|
This node has no links connected
to it
Info
|
Node name
|
Cause
|
Node is not connected to any links
|
Advice
|
Either delete node or connect node to network. The node may be lying on top of a link and require snapping in to existing link.
|
|
|
E0208
|
Top Level must be higher than Bottom
Level
Info
|
Reservoir name
|
Cause
|
Top Water Level value is greater than Reservoir Bottom Level on Reservoir Parameters Page / Reservoir Grid
|
Advice
|
Check reservoir parameters
|
|
|
E0211
|
Value out of range <range of valid
values>
Info
|
Float Valve name
|
Cause
|
Inlet Level value of Float valve < Bottom Water Level of associated Reservoir or > Top Water Level + (0.5 x Depth) of associated Reservoir
|
Advice
|
Check Float Valve and assocaited Reservoir parameters
|
|
|
E0217
|
Depths should be in ascending order
Info
|
Reservoir name
|
Cause
|
Entries in the depth-volume grid on the Reservoir Parameters Page must be in order of ascending depth
|
Advice
|
Check depth-volume grid entries
|
|
|
E0218
|
Volume should increase with Depth
Info
|
Reservoir name
|
Cause
|
Entries in the depth-volume grid on the Reservoir Parameters Page should show an increase in volume with depth
|
Advice
|
Check depth-volume grid entries
|
|
|
E0232
|
head (<index>) Heads should
be in descending order
Info
|
Pump Name. Grid row entry (index) of Q-H-P grid on Pump Curve Page.
|
Cause
|
Pump Head values do not decrease with increase in flow values in Q-H-P grid on Pump Curve Page.
|
Advice
|
Check entry in Q-H-P grid. Check pump curve characteristics entered in Q-H-P grid.
|
|
|
E0233
|
flow (<index>) Efficiency is
out of range (0 to 100)
Info
|
Pump Name. Grid row entry (index) of Q-H-P grid on Pump Curve Page.
|
Cause
|
Efficiency calculated from Q-H-P values is outside acceptable range for the indicated entry in the Q-H-P grid.
|
Advice
|
Check entry in Q-H-P grid. Check pump curve characteristics entered in Q-H-P grid.
|
|
|
E0234
|
flow (<index>) Velocity in
the pump outlet pipe is out of range <range of valid values>
Info
|
Pump Name. Grid row entry (index) of Q-H-P grid on Pump Curve Page.
|
Cause
|
Velocity calculated from Q-H-P values and diameter of pump outlet pipe is outside acceptable range for the indicated entry in the Q-H-P grid.
|
Advice
|
Check entry in Q-H-P grid. Check pump curve characteristics entered in Q-H-P grid. Check diameter of pump outlet pipe.
|
|
|
E0303
|
This node is not in the selected
subnetwork
Info
|
Valve type. Valve name. Range of Valid values.
|
Cause
|
Value specified in Valve diameter field in Valve Parameters Page / Valve Grid is out of acceptable range (either less than 10% of pipe diameter or greater than pipe diameter).
|
Advice
|
Enter valid diameter value for valve.
|
|
|
E0323
|
Value out of range <range of valid
values>
Info
|
Valve type. Valve name. Range of Valid values.
|
Cause
|
Value specified in Valve diameter field in Valve Parameters Page / Valve Grid is out of acceptable range (either less than 10% of pipe diameter or greater than pipe diameter).
|
Advice
|
Enter valid diameter value for valve.
|
|
|
E0325
|
Value 0 or missing
Info
|
Valve type. Valve name.
|
Cause
|
Valve diameter field in Valve Parameters Page / Valve Grid is either blank or contains zero value.
|
Advice
|
Enter valid diameter value for valve.
|
|
|
E0329
|
This node is not a reservoir
Info
|
Float valve name
|
Cause
|
The "To Node" of a float valve must be a reservoir node
|
Advice
|
Check that float valve is connected directly to a reservoir node. Check direction of float valve is correct.
|
|
|
E0330
|
Value exceeds reservoir depth (<reservoir
depth>)
Info
|
Float valve name
|
Cause
|
Value of regulating range on Float Valve/Inlet Parameters Page / Float Valve/Inlet Grid is greater than reservoir depth.
|
Advice
|
Check regulating range value and reservoir depth. (Typical regulating range value is 0.5 m)
|
|
|
E0330
|
Value out of range (<range of
valid values>)
Info
|
Float valve name. Minimum and maximum acceptable regulating range values.
|
Cause
|
Value of regulating range on Float Valve/Inlet Parameters Page / Float Valve/Inlet Grid is too small or too large.
|
Advice
|
Check regulating range value. (Typical regulating range value is 0.5 m)
|
|
|
E0333
|
Value out of range (0.10m to
<Reservoir depth>)
Info
|
Float valve name. Minimum and maximum acceptable control depth values.
|
Cause
|
Value of Control Depth of reported Float Valve is < 0.10m or > associated Reservoir depth
|
Advice
|
Check Control Depth value.
|
|
|
E0403
|
Too many profile entries <limit>
Info
|
Pump Station name. Maximum number of entries permitted.
|
Cause
|
There are too many entries in the profile grid on the Pump Control Data page
|
Advice
|
Reduce number of profile entries to within limit
|
|
|
E0404
|
Value exceeds depth in control reservoir
<reservoir depth>
Info
|
Pump Station name. Control Reservoir maximum depth.
|
Cause
|
Applicable to Pump Stations of Mode of Control type PLAN or FLOW using a Control Reservoir
Pump Station Pressure On value > Control Reservoir maximum depth
|
Advice
|
Check Pump Station Control Parameters and Reservoir Parameters
|
|
|
E0405
|
Value exceeds depth in control reservoir
Info
|
Pump Station name.
|
Cause
|
Applicable to Pump Stations of Mode of Control type PLAN or FLOW using a Control Reservoir
Pump Station Pressure Off value > Control Reservoir maximum depth
|
Advice
|
Check Pump Station Control Parameters and Reservoir Parameters
|
|
|
E0409
|
Cannot find this node in the network
Info
|
Pump Station name
|
Cause
|
The control node specified on the Pump Control Page / Pump Station Grid does not exist in the network, or a control node has not been specified.
|
Advice
|
Check control node specified on Pump Control Page
|
|
|
E0410
|
on (<index>) Value is out of
range (<reservoir depth range>)
Info
|
Pump Station name. Control Node (Reservoir) depth range.
|
Cause
|
May occur at a pump station where mode of control used is AUTO or PROF.
- AUTO - the pump ON pressure specified on the Pump Control Data Page is outside the reservoir depth range of the Control Reservoir specified on the Pump Control page / Pump Station grid.
- PROF - the Target Deviation On value is not within range:
- Control Node is a Reservoir - the Target Deviation On value is greater than +/- half the reservoir depth of the Control Reservoir, specified on the Pump Control page / Pump Station grid.
- Control Node is a Node - the Target Deviation On value is < -999.5m or > 99.5m.
|
Advice
|
Check pump ON pressure / Target Deviation On
|
|
|
E0412
|
off (<index>) Value is out
of range (<reservoir depth range>)
Info
|
Pump Station name. Control Node (Reservoir) depth range.
|
Cause
|
May occur at a pump station where mode of control used is AUTO or PROF.
- AUTO - the pump OFF pressure specified on the Pump Control Data Page is outside the reservoir depth range of the Control Reservoir specified on the Pump Control page / Pump Station grid.
- PROF - the Target Deviation Off value is not within range:
- Control Node is a Reservoir - the Target Deviation Off value is greater than +/- half the reservoir depth of the Control Reservoir, specified on the Pump Control page / Pump Station grid.
- Control Node is a Node - the Target Deviation Off value is < -999.5m or > 99.5m.
|
Advice
|
Check pump OFF pressure / Target Deviation Off
|
|
|
E0416
|
Initial speed (<index>) value is out of
range (<minimum speed to maximum speed>)
Info
|
Pump Station name
|
Cause
|
Pump Station pump Initial Speed value < Minimum Speed of pump or > Maximum Speed of pump
|
Advice
|
Check Pump Control Parameters and Pump Data parameters
|
|
|
E0417
|
pump_status_flags (<index>) Status
flags should be 0 or 1
Info
|
Pump Station name
|
Cause
|
Applicable to Pump Station of type = PLAN
A value in the pump status flags field specified on the Pump Control Page is not equal to 0 or 1.
|
Advice
|
Check status flags entries. 0 = OFF, 1 = ON
|
|
|
E0418
|
pump_status_flags (<index>)
Status flags count should be <no. of pumps in station>
Info
|
Pump Station name
|
Cause
|
The number of pump status flags specified on Pump Control Page is not the same as the number of pumps in the pump station
|
Advice
|
Enter status flag values for all pumps in the pump station
|
|
|
E0418
|
pump_availability_flag (<index>)
Availability flags count should be 0 or <no. of pumps in station>
Info
|
Pump Station name
|
Cause
|
The number of pump availability flags specified on Pump Control Page is not zero or the same as the number of pumps in the pump station
|
Advice
|
Enter availability flag values for all pumps in the pump station or remove all availability flags.
If availability flags are not specified, it will be assumed that the pump is available.
|
|
|
E0419
|
There must be at least one profile
entry for PROF mode
Info
|
Pump Station name
|
Cause
|
There is no data in the Date & Time/Target Pressure Depth grid on the Pump Control Data Page.
|
Advice
|
Enter values into Date & Time/Target Pressure Depth grid for Pump Station
|
|
|
E0420
|
Target_pressure_depth (<index>)
Value exceeds reservoir depth (<reservoir depth>)
Info
|
Pump Station name. Number of entry in Date & Time/Target Pressure Depth grid on Pump Control Data page. Control Node (Reservoir) depth.
|
Cause
|
May occur at a pump station where mode of control used is PROF. The target pressure depth specified on the Pump Control Data Page is outside the reservoir depth range of the Control Reservoir specified on the Pump Control page / Pump Station grid.
|
Advice
|
Check target pressure depth specified in Date & Time/Target Pressure Depth grid.
|
|
|
E0422
|
Pump <pump no.> Date & Time <row no.> Dates should be in ascending order
Info
|
Pump Station name. Number of entry in time varying profile grid on Pump Control Data page.
|
Cause
|
May occur at a pump station where mode of control used is AUTO, PROF or TFLW.
There are duplicate date-times in the time varying profile grid, or date-time has not been specified for rows in the time varying profile grid.
(If there is only one row in the time varying profile grid, it is not necessary to specify a date-time. If there are multiple rows in the grid, date-time must be specified for each row.)
|
Advice
|
Review time varying profile data in the Pump Control Data page.
|
|
|
E0424
|
Too many profile entries <limit>
Info
|
Name of control valve. Maximum number of entries permitted.
|
Cause
|
There are too many entries in the profile grid on the Pump Control Data page
|
Advice
|
Reduce number of profile entries to within limit
|
|
|
E0425
|
depth (<index>) Value exceeds
reservoir depth; Value exceeds reservoir depth
Info
|
Name of control valve. Profile grid entry index (where appropriate).
|
Cause
|
May occur when a valve is controlled as a Pressure Controlled Valve (PCV), a Pressure/Flow Valve (PFV) or an Open/Closed Valve (OCV).
For PCV/PFV: depth specified in the control data grid on the Valve Control Page is greater than the control node (reservoir) depth.
For OCV: Pressure Open/Closed value is greater than the control node (reservoir) depth.
|
Advice
|
Check depth/pressure entries on the Valve Control Page
|
|
|
E0428
|
Network is not interconnected. Check
connectivity
Info
|
None
|
Cause
|
There are disconnected subnetworks present.
|
Advice
|
If this is intentional, check the Disconnected System box on the Run Scheduler to run simulations for all disconnected subnetworks. Alternatively, check network connectivity using the Connectivity Trace facility.
|
|
|
E0429
|
Minimum speed (<index>) cannot be greater than
Maximum speed
Info
|
Pump Station name
|
Cause
|
Value specified in Maximum speed field of pump curve is greater than value specified in Minimum Speed field.
|
Advice
|
Check the Maximum speed and Minimum speed values on the Pump Data page of the Pump Station Property Sheet.
|
|
|
E0430
|
Pump <index>: % Speed On must be
between % Speed Off and 100
Info
|
Pump Station name
|
Cause
|
Applies to pump stations of Control Mode AUTO or PROF.
% Speed On value is less than % Speed Off value, or % Speed On value is greater than 100.
(Reverse logic cannot be applied to pumps controlled by pump speed.)
|
Advice
|
Check the % Speed On and % Speed Off values on the Pump Control Data page of the Pump Station Property Sheet.
|
|
|
E0430
|
Pump <index>: % Speed Off must be
between 0 and % Speed On
Info
|
Pump Station name
|
Cause
|
Applies to pump stations of Control Mode AUTO or PROF.
% Speed Off value is less than 0 or greater than % Speed On value.
(Reverse logic cannot be applied to pumps controlled by pump speed.)
|
Advice
|
Check the % Speed On and % Speed Off values on the Pump Control Data page of the Pump Station Property Sheet.
|
|
|
E0432
|
Pump <index> (variable speed):
On/Off must be set.
Info
|
Pump Station name
|
Cause
|
Applies to pump stations of Control Mode AUTO or PROF.
The pump identified in the error message is a variable speed pump. Pressure on/off values must be specified.
The Target Deviation On / Target Deviation Off fields for a PROF pump station, or the Pressure On / Off fields for an AUTO pump station, are not set or are set to equal values.
|
Advice
|
Check the On and Off values on the Pump Control Data page of the Pump Station Property Sheet.
|
|
|
E0435
|
Pump <index> (fixed speed): On/Off
must be set. (No variable speed pumps present.)
Info
|
Pump Station name
|
Cause
|
Applies to pump stations of Control Mode AUTO, PROF or TFLW.
The pumping station does not include a variable speed pump and the
Target Deviation On / Pressure On and Target Deviation Off / Pressure Off values for a fixed speed pump in the station are equal or not set.
|
Advice
|
Check the On and Off values on the Pump Control Data page of the Pump Station Property Sheet.
|
|
|
E0436
|
Pump <index> (fixed speed): must set
either On/Off or %speed-on/off
Info
|
Pump Station name
|
Cause
|
Applies to pump stations of Control Mode AUTO or PROF.
The identified fixed speed pump in the pumping station does not have (Target Deviation) On / Off or % Speed On / Off values set.
(Note: On / Off fields with equal values are treated as unset.)
|
Advice
|
Check the On and Off values on the Pump Control Data page of the Pump Station Property Sheet.
|
|
|
E0437
|
Pump regulation mixes normal and reverse
logic
Info
|
Pump Station/Control Valve name
|
Cause
|
Applies to pump stations of Control Mode AUTO or PROF or control valves of Mode OCV.
For pump stations:
Target Deviation On / Pressure On is greater than Target Deviation Off / Pressure Off for some pumps in the pumping station but less than Target Deviation Off / Pressure Off for others.
For valves:
Pressure Open is greater than Pressure Closed for some entries in the Control data grid but less than Pressure Closed for others.
|
Advice
|
For pump stations:
Check the On and Off values on the Pump Control Data page of the Pump Station Property Sheet.
For valves:
Check the Pressure Open and Closed values on the Valve Control page of the Control Valve Property Sheet.
|
|
|
E0444
|
Value Missing
Info
|
Name of the network object (pump station, reservoir, meter or pipe) to be optimised using BalanceNet.
|
Cause
|
There is an enabled value missing in the Flow Volume Constraints grid of the BalanceNet tab in the object property sheet.
|
Advice
|
Ensure that every enabled value of the Flow Volume Constraints grid is specified (disabled values are greyed out, therefore ignored during validation).
|
|
|
E0445
|
Max Fire Flow must be greater than
Min Fire Flow
Info
|
Name of Hydrant Node (if applicable)
|
Cause
|
Maximum Flow specified for use in a Fire Flow - Hydrant Testing simulation is greater than Minimum Flow specified.
|
Advice
|
Check the Maximum Flow and Minimum Flow fields on the Fire Flow Constraints Page of the Hydrant Node.
Check the Minimum and Maximum Flow fields of the Fire Flow Data being used in Fire Flow - Hydrant Testing simulation.
|
|
|
E0446
|
No nodes selected for hydrant testing
Info
|
None
|
Cause
|
There are no valid nodes in the selection chosen for use in a Fire Flow - Hydrant Testing simulation.
|
Advice
|
Check the correct selection list has been chosen for use in the Fire Flow - Hydrant Testing simulation.
Only nodes of type Hydrant and Node are valid nodes for Hydrant testing.
|
|
|
E0450
|
This link is not unique
Info
|
Link name
|
Cause
|
May occur where a link has the same From Node and To Node
|
Advice
|
Check link connectivity on GeoPlan. If the link forms a loop in the network, insert a node in the link.
|
|
|
E0504
|
The number of entries is not the
same as for the network
Info
|
Pump Station name
|
Cause
|
For pumping stations controlled using AUTO, PROF or TFLW modes, the number of entries in the Pump Initial Status grid on the Pump Control Data Page is not the same as the number of pumps in the pump station
|
Advice
|
Check number of Pump Initial Status entries
|
|
|
E0516
|
Cannot find this link in the network
Info
|
Control Valve name
|
Cause
|
The Control Pipe specified on the Valve Control Page / Control Valve grid does not exist in the network or has not been specified.
|
Advice
|
Check the Control Pipe field.
|
|
|
E0524
|
Initial depth cannot be greater than
reservoir depth <reservoir depth>
Info
|
Reservoir name
|
Cause
|
Value of initial depth on Reservoir Parameters Page / Reservoir Grid is greater than depth specified
|
Advice
|
Check initial depth and reservoir depth values are correct
|
|
|
E0542
|
Cannot find this node in the network
Info
|
Control Valve name
|
Cause
|
Applicable to valves of type: PRV, PCV, PFV, PSV and FMV:
Control Node has not been specified or does not exist in the network
|
Advice
|
Check Control Node has been specified
|
|
|
E0621
|
Outlet elevation must be >= Node
elevation
Info
|
Hydrant name
|
Cause
|
If Outlet Elevation value has been entered:
Outlet Elevation < Node Elevation
If no Outlet Elevation value:
Relative Head Elevation < 0.0
|
Advice
|
Check elevation values
|
|
|
E0622
|
Cannot have upstream links
Info
|
Well name
|
Cause
|
Well object is the To Node of a link
|
Advice
|
Check Well connectivity
|
|
|
E0623
|
Must have a single downstream link
Info
|
Well name
|
Cause
|
Well object is connected to < 1 link or > 1 link
|
Advice
|
Check Well connectivity
|
|
|
E0624
|
Must be linked to a pump object
Info
|
Well name
|
Cause
|
Well object is connected to a link other than a Pump Station
|
Advice
|
Check Well connectivity
|
|
|
E0777
|
UPC Script <no.> Warnings
<no.> Errors
Info
|
Regulator name
|
Cause
|
There are errors in the Global UPC Script or the local UPC Script at the regulator identified.
|
Advice
|
Test the UPC Script on the Global or local UPC page for further diagnostics.
|
|
|
E0870
|
No Electricity Tariff provided for Cost Management
Info
|
No additional information
|
Cause
|
Applicable to Cost Management Simulations and BalanceNet Simulations.
An Electricity Tariff has not been included in the Hydraulic Run Scheduler.
|
Advice
|
Select an Electricity Tariff for use in the Hydraulic Run Scheduler
|
|
|
E0871
|
No Pumping Stations (or Control Valves) chosen for Optimisation
Info
|
No additional information
|
Cause
|
Applicable to Cost Management Simulations and BalanceNet Simulations.
None of the Pump Stations or Control Valves in the network have been selected for optimisation (i.e. have the Cost Management box checked).
|
Advice
|
Check that the Control Data being used in the simulation is as expected.
|
|
|
E0872
|
Min Volume out of range (0% to 100%)
Info
|
Reservoir ID
|
Cause
|
Applicable to Cost Management Simulations and BalanceNet Simulations.
The Cost Management box in the Reservoir control data has been checked and the Minimum Volume optimisation parameter is less than 0% or greater than 100%.
|
Advice
|
Set the Minimum Volume Reservoir control data field to a valid value.
|
|
|
E0873
|
Max Volume out of range (0% to 100%)
Info
|
Reservoir ID
|
Cause
|
Applicable to Cost Management Simulations and BalanceNet Simulations.
The Cost Management box in the Reservoir control data has been checked and the Maximum Volume optimisation parameter is less than 0% or greater than 100%.
|
Advice
|
Set the Maximum Volume Reservoir control data field to a valid value.
|
|
|
E0874
|
Max Switches must be at least 1
Info
|
Pump Station ID
|
Cause
|
Applicable to Cost Management Simulations and BalanceNet Simulations.
The Cost Management box in the Pump Station control data has been checked and the Max Switches value is less than 1.
|
Advice
|
Set the Max Switches Pump Station control data field to a value greater than 1.
|
|
|
E0875
|
Min On Time cannot be negative
Info
|
Pump Station ID
|
Cause
|
Applicable to Cost Management Simulations and BalanceNet Simulations.
The Cost Management box in the Pump Station control data has been checked and the Min On Time value is negative.
|
Advice
|
Set the Min On Time Pump Station control data field to a positive value.
|
|
|
E0876
|
Min Off Time cannot be negative
Info
|
Pump Station ID
|
Cause
|
Applicable to Cost Management Simulations and BalanceNet Simulations.
The Cost Management box in the Pump Station control data has been checked and the Min Off Time value is negative.
|
Advice
|
Set the Min Off Time Pump Station control data field to a positive value.
|
|
|
E0877
|
Electricity Tariff required for optimisation
Info
|
Pump Station ID
|
Cause
|
Applicable to Cost Management Simulations and BalanceNet Simulations.
The Cost Management box in the Pump Station control data has been checked and there is no Tariff Name specified.
|
Advice
|
Enter a Tariff Name in the Pump Station network data.
|
|
|
E0879
|
For a Turbine type the Mode of Control must be set to "TURB"
Info
|
Pumping Station name
|
Cause
|
The Turbine option on the Pumping Station Parameters Page has been checked, but the Mode of Control on the Pump Control page is not set to TURB.
|
Advice
|
Set Mode of Control on the Pump Control page to TURB
|
|
|
E0881
|
Cost management cannot be used for PST in this control mode
Info
|
Pump Station ID
|
Cause
|
Applicable to Cost Management Simulations and BalanceNet Simulations.
The Mode of Control of this pump station (Pump Control tab of the Pump Station property sheet) is not supported by the optimiser.
|
Advice
|
Uncheck the Cost Management box to run a simulation without optimisation of the pump station.
Change the pump station control mode to PLAN (BalanceNet and Cost Management) or PROF (Cost Management only) and carry out optimisation on the pump station.
|
|
|
E0882
|
Min Volume greater than Max Volume
Info
|
Reservoir ID
|
Cause
|
Applicable to Cost Management Simulations and BalanceNet Simulations.
The Cost Management box in the Reservoir control data has been checked and the Minimum Volume optimisation parameter is greater than the Max Volume parameter defined for the reservoir.
|
Advice
|
Check that the Reservoir Cost Management control values are as expected.
|
|
|
E0883
|
Target Volume out of range (Min Volume to Max Volume)
Info
|
Reservoir ID
|
Cause
|
Applicable to Cost Management Simulations and BalanceNet Simulations.
The Cost Management box in the Reservoir control data has been checked and the Target Volume value is less than the Min Volume or greater than the Max Volume optimisation parameter defined for the reservoir.
|
Advice
|
Check that the Reservoir Cost Management control values are as expected.
|
|
|
E0886
|
Min On Time longer than simulation period
Info
|
Pump Station ID
|
Cause
|
Applicable to Cost Management Simulations and BalanceNet Simulations.
The Cost Management box in the Pump Station control data has been checked and the Min On Time value is greater than the simulation period defined in the Schedule Hydraulic Run View.
|
Advice
|
Check that the Min Off Time value is as expected.
Adjust the simulation period if necessary.
|
|
|
E0887
|
Min Off Time longer than simulation period
Info
|
Pump Station ID
|
Cause
|
Applicable to Cost Management Simulations and BalanceNet Simulations.
The Cost Management box in the Pump Station control data has been checked and the Min Off Time value is greater than the simulation period defined in the Schedule Hydraulic Run View.
|
Advice
|
Check that the Min Off Time value is as expected.
Adjust the simulation period if necessary.
|
|
|
E0888
|
Control node for pump station used in optimisation should be a reservoir
Info
|
Pump Station ID
|
Cause
|
Applicable to Cost Management Simulations and BalanceNet Simulations.
The Cost Management box in the Pump Station control data has been checked and the Control Node is not a Reservoir node.
|
Advice
|
Optimisation cannot be carried out on a Pump Station with a control node that is not a Reservoir node.
Uncheck the Cost Management box to run a simulation without optimisation of the Pump Station.
Change the control node to a Reservoir node if possible to carry out optimisation on the Pump Station.
|
|
|
E0889
|
Optimisation profile time interval less than simulation timestep
Info
|
No additional information
|
Cause
|
Applicable to Cost Management Simulations.
The Profile Time Interval specified on the Cost Management Options dialog is less than the Timestep specified on the Schedule Hydraulic Run View.
|
Advice
|
Set the Profile Time Interval to be equal or greater to the simulation Timestep.
|
|
|
E0891
|
Only TCV valves can be used in
optimisation
Info
|
Valve ID
|
Cause
|
The Cost Management box in the Valve control data has been checked and the Valve is not a Time Controlled Valve (Mode ID = TCV)
|
Advice
|
Cost Management cannot be carried out on a Valve that is not of Mode ID 'TCV'.
Uncheck the Cost Management box to run a simulation without optimisation of the valve.
Change the valve to a time controlled valve to carry out optimisation on the valve.
|
|
|
E0893
|
Both UPC Object and UPC Scripts
Info
|
No additional information
|
Cause
|
Both a UPC Scenario and a Control Data containing UPC Scripts have been included in the Hydraulic Run Scheduler for use in a simulation.
|
Advice
|
Check that the correct Control Data and UPC Scenario have been selected in the Hydraulic Run View for the simulation.
|
|
|
E0901
|
Cannot find customer point <customer
point id> in the alternative customer demand table
Info
|
Node name
|
Cause
|
The Alternative Demand item validated with the current network does not have customer point data for the reported customer point name. The Alternative Demand should have a record for every customer point in the network.
|
Advice
|
Check the correct Alternative Demand object has been selected for validation.
Add a customer point record to the Alternative Demand or initialise the Alternative Demand if this has not been done already.
|
|
|
E0908
|
Invalid Polygon Name <Polygon ID>
Info
|
Node name
|
Cause
|
The Polygon referred to in the Polygon ID field in the Land Use tab of the Node Property Sheet does not exist.
This may be due to the polygon being renamed or deleted after land use demand was allocated.
|
Advice
|
Check the correct polygon object has been selected in the Land Use grid.
|
|
|
E0920
|
<Object Group member ID> does not
exist
Info
|
Object Group name, Object Group member name
|
Cause
|
The reported Object Group member could not be found in the network. This may be due to renaming or deletion of objects.
|
Advice
|
Check that the object IDs in the objects grid on the Object Group Definition Page of the Object Group Property Sheet are as expected.
|
|
|
E9000
|
A value must be specified for this
field
Info
|
Object Type. Object name. Field name.
|
Cause
|
InfoWorks WS cannot compute solution without data in this field
|
Advice
|
Enter a valid value in this field
|
|
|
E9001
|
Value too large. Maximum value is
<maximum value>
Info
|
Object Type. Object name. Field name. Maximum acceptable value
|
Cause
|
The maximum acceptable value in the field indicated by the error message has been exceeded.
|
Advice
|
Enter a valid value in this field
|
|
|
E9001
|
Value too small. Minimum value
is <minimum value>
Info
|
Object Type. Object name. Field name. Minimum acceptable value
|
Cause
|
The value in the field indicated by the error message is less than the minimum acceptable value
|
Advice
|
Enter a valid value in this field
|
|
|
E9002
|
<field> (<index>) Value
too large. Maximum value is <maximum value>
Info
|
Object Type. Object name. Field name. Field entry index. Maximum acceptable value
|
Cause
|
The maximum acceptable value in the field indicated by the error message has been exceeded.
|
Advice
|
Enter a valid value in this field
|
|
|
E9002
|
<field> (<index>) Value
too small. Minimum value is <minimum value>
Info
|
Object Type. Object name. Field name. Field entry index. Minimum acceptable value
|
Cause
|
The value in the field indicated by the error message is less than the minimum acceptable value
|
Advice
|
Enter a valid value in this field
|
|
|
E9010
|
US node not in network
Info
|
Link Name
|
Cause
|
From Node ID does not exist in the network. The node may have been deleted or renamed.
|
Advice
|
Check link connectivity on GeoPlan
|
|
|
E9011
|
DS node not in network
Info
|
Link Name
|
Cause
|
To Node ID does not exist in the network. The node may have been deleted or renamed.
|
Advice
|
Check link connectivity on GeoPlan
|
|
|
E9012
|
Both ends are connected to the same
node
Info
|
Link Name
|
Cause
|
Link From Node and To Node are the same. This may occur where a link forms a loop.
|
Advice
|
Check link connectivity on GeoPlan. If the link forms a loop in the network, insert a node in the link.
|
|
|
W0017
|
minimal_speed (<index>) Rotational
speed is less than 40% nominal_speed
Info
|
Pump Station name. Pump entry index.
|
Cause
|
The minimum rotational speed specified on the Pump Data page for the pump indicated is less than 40% of the nominal speed specified on the Pump Curve page
|
Advice
|
Check minimum speed specified for pump
|
|
|
W0020
|
no_of_stages (<index>) No.
of stages zero or missing (one stage assumed)
Info
|
Pump Station name
|
Cause
|
No. of stages field on Pump Data Page either contains zero value or is blank. Default value of 1 will be assumed.
|
Advice
|
Enter a value in the No. of stages field to remove validation warning message.
|
|
|
W0022
|
None of the pumps in the station
can provide the duty head
Info
|
Pump Station name
|
Cause
|
The combination of pumps in the pump station cannot provide the duty head
|
Advice
|
InfoWorks WS will use the available head, so no computational inaccuracy will occur. Check the pump data for the pumping station.
|
|
|
W0028
|
pump_curve_id (<index>) Pump
not found in pump list (no pump curve)
Info
|
Pump Station name
|
Cause
|
Pump Curve ID specified on Pump Data Page does not exist in Pump Grid
|
Advice
|
Check that correct Pump Curve ID has been specified. Check that pump curve data has been entered in the Pump Grid.
|
|
|
W0032
|
Direct Demand in Category <demand
category name> has no factor - ignored
Info
|
Node name to which demand category has been assigned. Name of demand category.
|
Cause
|
Applicable when a Demand Diagram has been included for validation.
A demand category of type Direct has been specified on the Node Demand Page, but no corresponding Direct Demand Factor has been specified.
|
Advice
|
Check that the correct Demand Diagram has been selected in the Network Validation dialog / Run Scheduler. Check that the correct demand category has been assigned to the node.
Enter a Direct Demand Factor if required.
|
|
|
W0113
|
Duplicate name <Old Demand Category name> changed to <New
Demand Category Name>
Info
|
None
|
Cause
|
May occur if a Demand Diagram has been imported from an external source and the import file contains duplicate demand category names:
- Demand categories in the file used for import have been defined with the same name.
- On import to a Demand Diagram, the demand categories with duplicate names are renamed by InfoWorks to generate unique names
- On validation, W0113 warning messages will be displayed in the Output Window describing the changes made to demand category names.
|
Advice
|
Check the files from which the Demand Diagram was imported.
|
|
|
W0119
|
Valve curve <valve curve name>
not recognised. PLUG used by default
Info
|
Valve name
|
Cause
|
The Valve Curve ID specified on the Valve Parameters Page / Valve Grid does not exist in the Valve Curve grid. The built in curve for a PLUG valve will be used by default.
|
Advice
|
Check that correct Valve Curve ID has been specified. Check that valve curve data has been entered in the Valve Grid.
|
|
|
W0323
|
Value out of range <range of valid valve diameter values>
Info
|
Valve type. Valve name. Range of Valid values.
|
Cause
|
Applicable to Checked In networks only.
Value specified in Valve diameter field in Valve Parameters Page / Valve Grid is out of acceptable range (either less than 10% of pipe diameter or greater than pipe diameter).
|
Advice
|
Check out the network and enter a valid diameter value for valve.
|
|
|
W0326
|
Valve curve multiplier <loss coeff. multiplier> out of recommended range <range ofvalid values>
Info
|
Valve or Hydrant name
|
Cause
|
Loss Coeff. (Open) / Fully Open Loss Coeff > valid valve curve multiplier
|
Advice
|
Check value entered in Loss Coeff. (Open) field.
|
|
|
W0326
|
Valve curve multiplier <loss coeff. multiplier> out of range <range of valid values>.Loss Coeff. (Open) will be set to minimum value
Info
|
Valve or Hydrant name
|
Cause
|
Loss Coeff. (Open) / Fully Open Loss Coeff < valid valve curve multiplier
If the value is not changed the default value will be assumed.
|
Advice
|
Check value entered in Loss Coeff. (Open) field.
|
|
|
W0327
|
Value missing or out of range (1.0-2.0)
(will default to 1.25)
Info
|
Pump Station name
|
Cause
|
Electric / Hydraulic Power ratio field < 1.0 or > 2.0
|
Advice
|
Check value entered in Electric / Hydraulic Power field.
If the value is not changed the default value of 1.25 will be assumed.
|
|
|
W0334
|
Value 0 or missing (will default to
Reservoir depth)
Info
|
Float Valve name
|
Cause
|
The Control Depth field of the reported Float Valve is 0 or has not been specified
|
Advice
|
Enter a valid Control Depth for the float valve.
If the field is left empty or zero, the depth of the associated Reservoir will be assumed.
|
|
|
W0411
|
The control strategy for this pump
does not turn it on
Info
|
Pump Station name
|
Cause
|
The controls specified on the Pump Control Data Page are such that none of the pumps in the pump station will be turned on.
|
Advice
|
This may be intentional. If not, check the pump controls.
|
|
|
W0413
|
Profile Times out of range
Info
|
Object name
|
Cause
|
Time varying profile defined in the Control Data lies outside of the Control Start and End Time.
|
Advice
|
Check that the Control Time Interval and the time varying profile date-times are as expected.
|
|
|
W0415
|
Control Levels on/off are equal and will
be ignored
Info
|
Pump Station name
|
Cause
|
Applies to pump stations of Control Mode AUTO or PROF.
Pump Station Pressure On / Target Deviation On value = Pressure Off / Target Deviation Off value.
|
Advice
|
Check the On / Off values on the Pump Control Data page of the Pump Station Property Sheet.
|
|
|
W0416
|
Speed (<index>) value is out of
range (<minimum speed to maximum speed>)
Info
|
Pump Station name
|
Cause
|
Pump Station pump Initial Speed value < Minimum Speed of pump or > Maximum Speed of pump
|
Advice
|
Check Pump Control Parameters and Pump Data parameters
|
|
|
W0428
|
Network is not interconnected. Check
connectivity.
Info
|
None
|
Cause
|
There are disconnected subnetworks present.
|
Advice
|
If this is intentional, check the Disconnected System box on the Run Scheduler to run simulations for all disconnected subnetworks. Alternatively, check network connectivity using the Connectivity Trace facility.
|
|
|
W0431
|
Pump <index>: %Speed Off/On is below
minimal speed of a variable pump
Info
|
Pump Station Name
|
Cause
|
Applies to pump stations of Control Mode AUTO or PROF.
% Speed On / Off value for the pump identified is less than the Minimum Speed value for any of the variable speed pumps in the pumping station.
|
Advice
|
Check the % Speed On and % Speed Off values on the Pump Control Data page of the Pump Station Property Sheet.
|
|
|
W0433
|
Pump <index> (fixed speed): On/Off
will be ignored because %Speed-on/off is set. (Variable speed pumps are
present.)
Info
|
Pump Station Name
|
Cause
|
Applies to pump stations of Control Mode AUTO or PROF.
Both %Speed On / Off and (Target Deviation) On / Off values have been defined for the fixed speed pump identified.
|
Advice
|
Check the On and Off values on the Pump Control Data page of the Pump Station Property Sheet.
% Speed On / Off values will supersede (Target Deviation) On / Off values.
|
|
|
W0434
|
Pump <index>: %Speed On and %Speed
Off are equal and will be ignored
Info
|
Pump Station Name
|
Cause
|
Applies to pump stations of Control Mode AUTO or PROF.
% Speed On and % Speed Off values are the same for the pump identified.
|
Advice
|
Check the On and Off values on the Pump Control Data page of the Pump Station Property Sheet.
(% Speed values are treated as unset. Pressure On / Off values will be used for pump switching instead.)
|
|
|
W0437
|
Multiple VSP Regulation requires identical available pumps (except cut off level & duty flow) with valid pump curves
Info
|
Pump Station Name
|
Cause
|
Applies to pump stations of Control Mode AUTO, PROF or TFLW, with Multiple VSP Regulation option checked.
The pump station includes more than one variable speed pump.
The values specified in the pump data fields for the variable speed pumps are not the same . (Cut off level and Duty flow may vary.)
If variable speed pumps are not identical the pump station will only regulate using the first available variable speed pump. Other pumps will be run at full speed.
|
Advice
|
Check the values specified in the Pump Data tab of the pump station property sheet.
|
|
|
W0438
|
Fixed speed pump regulation using a
mixture of pressure and speed criteria.
Info
|
Pump Station Name
|
Cause
|
Applies to pump stations of Control Mode AUTO or PROF.
The pump station includes more than one fixed speed pump. Some of the fixed speed pumps are controlled by speed and others by pressure.
|
Advice
|
Check the On and Off values on the Pump Control Data page of the Pump Station Property Sheet.
(% Speed On / Off values will supersede (Target Deviation) On / Off values.)
|
|
|
W0439
|
Pump regulation uses reverse logic
Info
|
Pump Station Name
|
Cause
|
Applies to pump stations of Control Mode AUTO or PROF.
(Target Deviation) On value is greater than (Target Deviation) Off value.
|
Advice
|
Check the On and Off values on the Pump Control Data page of the Pump Station Property Sheet.
(Pressure On value less than Pressure Off value expected.)
|
|
|
W0440
|
target_pressure_depth(<index>) is
unset and will be treated as zero
Info
|
Pump Station Name
|
Cause
|
Applies to pump stations of Control Mode PROF.
A Target Pressure Depth value has not been set in the grid on the Pump Control Data Page of the Pump Station Property Sheet.
|
Advice
|
Check the Target Pressure Depth values on the Pump Control Data page of the Pump Station Property Sheet.
|
|
|
W0444
|
Value missing
Info
|
Hydrant Name
|
Cause
|
There is no Zone Min Residual Pressure value
|
Advice
|
This may be intentional if a Zone Min Residual Pressure value is to be used from a Fire Flow object.
|
|
|
W0447
|
Hydrant testing not supported for this
node type
Info
|
Node Name
|
Cause
|
Node is not of type Node or Hydrant
|
Advice
|
For information.
The reported node will not be tested during a Fire Flow - Hydrant Testing simulation.
|
|
|
W0525
|
Negative value treated as unset
Info
|
Node Name
|
Cause
|
A negative concentration value has been entered in the water quality profile grid.
Applicable to water quality source type: Fixed concentration, Additional concentration and Concentration booster.
|
Advice
|
For information.
The concentration source will be turned off for the period that the concentration value is set to < 0.
This allows inflow from upstream pipes to set concentration at the node during the period that the concentration source is switched off.
|
|
|
W0881
|
BalanceNet cost management cannot be used for PST in this control mode
Info
|
Pump Station ID
|
Cause
|
Applicable to BalanceNet Simulations.
The Cost Management box has been checked for a Pump Station with Mode of Control other than PLAN.
Only Pump Stations with Mode of Control PLAN will be optimised when carrying out a BalanceNet simulation.
|
Advice
|
For information.
The Pump Station will not be optimised when carrying out a BalanceNet simulation.
|
|
|
W0884
|
Min Volume above 90%
Info
|
Reservoir ID
|
Cause
|
The value in the Reservoir control field Min Volume (used in Optimisation simulations) is greater than 90%
|
Advice
|
For information.
Check that the Min Volume value is as expected.
|
|
|
W0885
|
Max Volume below 10%
Info
|
Reservoir ID
|
Cause
|
The value in the Reservoir control field Max Volume (used in Optimisation simulations) is less than 10%
|
Advice
|
For information.
Check that the Max Volume value is as expected.
|
|
|
W0900
|
Cannot find node in the alternative node
demand table
Info
|
Node name
|
Cause
|
The Alternative Demand item validated with the current network does not have data for the reported node name. The Alternative Demand should have a record for every node that is in the network.
|
Advice
|
Check the correct Alternative Demand object has been selected for validation.
Add a node record to the Alternative Demand or initialise the Alternative Demand if this has not been done already. A record can be added via the Node Demand page of the Alternative Demand Grid.
|
|
|
W0903
|
Cannot find alternative node in the
network
Info
|
Alternative Demand Node ID
|
Cause
|
The Alternative Demand currently associated with the network contains a Node ID that does not exist in the network.
|
Advice
|
For information.
Check that the Alternative Demand associated with the network is as expected.
|
|
|
W0906
|
Cannot find Node in the Alternative Land Use Demand Table
Info
|
Node name
|
Cause
|
The Alternative Demand item validated with the current network does not have data for the reported node name. The Alternative Demand should have a record for every node that is in the network.
|
Advice
|
Check the correct Alternative Demand object has been selected for validation.
Add a node record to the Alternative Demand or initialise the Alternative Demand if this has not been done already. A record can be added via the Land Use Demand page of the Alternative Demand Grid.
|
|
|
W0907
|
Cannot find Alternative Land Use Node in the
Network
Info
|
Alternative Demand Node ID
|
Cause
|
The Alternative Demand currently associated with the network contains a Node ID that does not exist in the network.
|
Advice
|
For information.
Check that the Alternative Demand associated with the network is as expected.
|
|
|
W0921
|
<Object Group Member ID> already in
list
Info
|
Object Group name, Object Group member name
|
Cause
|
The reported Object Group member ID has been added to the Object Group more than once.
|
Advice
|
Check the objects grid on the Object Group Definition Page of the Object Group Property Sheet for duplicate object IDs.
|
|
|
W9001
|
Value above recommended value of 199.00m
Info
|
Pump Station name. Field name (Pressure On / Pressure Off).
|
Cause
|
The recommended maximum value for Pressure On or Pressure Off for the pump station indicated has been exceeded.
Applies to PLAN and FLOW pump stations.
|
Advice
|
Check that a valid value has been entered in the Pressure On / Pressure Off field
|
|
|
W9002
|
target_pressure_depth <(index)> Value above recommended value of 199.00 m
Info
|
Pump Station name. Field name. Field entry index. Maximum recommended value.
|
Cause
|
The recommended maximum value for Target pressure depth for the pump station indicated has been exceeded.
Applies to PROF pump stations.
|
Advice
|
Check that a valid value has been entered in the Target pressure depth field
|
|
|