Leak Detection Survey Data Fields
Leak Detection Survey data can be edited on either the Leak Detection Grid Window of the Survey Grid or the Leak DetectionProperty Sheet.
To view and edit all leak detection data, use the Property Sheet.
The following describes all the data which can be used to define a leak detection survey.
Fields that are common to the majority of objects can be found in the Common Fields topic.
Leak Detection Data
Database Table Name: wams_leak_detection
Field Name |
Help Text |
Database Field |
Size |
Precision |
Default |
Error Lower Limit |
Error Upper Limit |
Warning Lower Limit |
Warning Upper Limit |
||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ID |
The name of the object. The ID is the primary key in the database for the network object. This means that the ID field of each object must be unique for all objects of the same object type. |
id |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||
Node ID |
Node at which leak detection survey was carried out. |
node_id |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||
Pipe ID | Pipe at which leak detection survey was carried out. | pipe_id | Text | 40 | 0 | ||||||||||||||
Leak distance | Distance along pipe to leak location (if leak detected). | leak_distance | Double | L | 2 | ||||||||||||||
X coordinate |
X coordinate of the object. The coordinates of the Leak Detection Survey may be defaulted, in which case, the order of precedence of calculating coordinates is as follows:
|
x |
Double |
|
XY |
2 |
|
|
|
|
|
||||||||
Y coordinate |
Y coordinate of the object. The coordinates of the Leak Detection Survey may be defaulted, in which case, the order of precedence of calculating coordinates is as follows:
|
y |
Double |
|
XY |
2 |
|
|
|
|
|
||||||||
Leak detection type |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
leak_detection_type | Text | 40 | 0 | ||||||||||||||
Location |
Address or description of site at which associated asset is located. |
location |
Text |
100 |
|
0 |
|
|
|
|
|
||||||||
Leak detected | Check this field to indicate that a leak was detected during the survey. | leak_detected | Boolean | 0 | |||||||||||||||
Leak severity |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
leak_severity | Text | 40 | 0 | ||||||||||||||
Date loggers installed | Date-time at which logger was installed. | date_loggers_installed | Date / Time | 0 | |||||||||||||||
Date loggers removed | Date-time at which logger was removed. | date_loggers_removed | Date / Time | 0 | |||||||||||||||
Scheduled Task fields | See Common Data Fields - Scheduled Task fields for details of all fields in the Schedule Info, Progress Info and Resources sections of the property sheet. | ||||||||||||||||||
Attachments |
Click the button to display the Attachments Editor, used to attach and manage photos, sketches and other files associated with the network object. See Attachments Editor and Common Data Fields for further details. |
attachments | Array | ||||||||||||||||
General properties fields | See Common Data Fields for details of field in the General properties section of the property sheet. | ||||||||||||||||||
User defined properties fields | See Common Data Fields - User Fields for details of fields in the User defined properties section of the property sheet. |