Acoustic Survey Data Fields

Information relating to an Acoustic Survey can be viewed and edited on the Acoustic Survey Grid Window of the Survey Grid or on the Acoustic Survey Property Sheet.

To view and edit all acoustic survey data, use the Property Sheet.

The following describes all the data which can be used to define an acoustic survey.

Common Data Fields

Fields that are common to the majority of objects can be found in the Common Fields topic.

Acoustic Survey Data

Database Table Name: cams_acoustic_survey

Show Columns

Database Names

Size, Type and Units

Defaults and Error Limits

Field Name

Help Text

Database Field

Data Type

Size

Units

Precision

Default

Error Lower Limit

Error Upper Limit

Warning Lower Limit

Warning Upper Limit

ID

Unique ID for the survey.

id

Text

40

 

0

 

 

 

 

 

US node ID

ID of the node upstream of the pipe surveyed.

us_node_id

Text

40

 

0

 

 

 

 

 

DS node ID

ID of the node downstream of the pipe surveyed.

ds_node_id

Text

40

 

0

 

 

 

 

 

Link suffix

Suffix of the pipe surveyed.

link_suffix

Text

1

 

0

 

 

 

 

 

Location

Address or description of site at which survey is located.

location

Text

100

 

0

 

 

 

 

 

Description A description of the survey. description Text 100   0          

Survey date

Survey date.

survey_date

Date / Time

100

 

0

 

 

 

 

 

Test version

Version of the related SewerBatt XML file.

test_version

Text

10

 

0

 

 

 

 

 

Operator

The name of the person responsible for carrying out the inspection of the pipeline.

operator

Text

100

 

0

 

 

 

 

 

Start manhole

Manhole ID at start of survey.

start_manhole

Text

40

 

0

 

 

 

 

 

Finish manhole

Manhole ID at end of survey.

finish_manhole

Text

40

 

0

 

 

 

 

 

Pipe length

The length of the construction units used in the pipe. (Also referred to as pipe joint length).

pipe_length

Double

 

L

2

 

 

 

 

 

Diameter

Pipe diameter.

diameter

Double

 

CAMS_PS

0

 

0

 

 

 

Water level

Level of water in the pipe.

Water level diagram

water_level

Double

 

CAMS_P

0

 

 

 

 

 

Temperature

Temperature at time of survey.

temperature

Text

3

CF

0

 

 

 

 

 

Amp level

Amplitude level used in the excitation signal (i.e. 0 to 9).

amp_level

 

 

 

0

 

 

 

 

 

GPS easting

Eastward-measured distance or x-coordinate of the survey.

gps_easting

Double

 

 

8

 

 

 

 

 

GPS northing

Northward-measured distance or y-coordinate of the survey.

gps_northing

Double

 

 

8

 

 

 

 

 

Bearing

Direction the pipe faces as measured from the GPS point.

bearing

Double

 

ANGLE

0

 

 

 

 

 

Report date

Date of the associated report.

report_date

Date / Time

 

 

0

 

 

 

 

 

Report version

Version of the associated report.

report_version

Text

10

  0          

Condition

The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog.

condition

Text

10

 

0

 

 

 

 

 

Grade

grade

Long Integer

 

 

0

 

 

 

 

 

Analysis is valid up to

analysis_is_valid_up_to

Double

 

L

2

 

 

 

 

 

Defect strength

defect_strength

Double

 

 

2

 

 

 

 

 

Defect energy

defect_energy

Double

    2          

Noise energy

noise_energy

Double

 

 

2

 

 

 

 

 

Unrelated energy

unrelated_energy

Double

 

 

2

 

 

 

 

 

RAG value

rag_value

Double

 

 

2

 

 

 

 

 

Defects

Show Columns

Database Names

Size, Type and Units

Defaults and Error Limits

Database Table Name: cams_acoustic_survey_details

 

Position in Data Structure

Field Name

Help Text

Database Field

Data Type

Size

Units

Default

Error Lower Limit

Error Upper Limit

Warning Lower Limit

Warning Upper Limit

1

Distance

Distance along pipe

distance

Double

 

L

 

0

 

 

 

2

Code

Defect code (SewerBatt standard)

The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog.

code

Text

12

 

 

0

 

 

 

3

%

Intrusion fraction

percentage

Double

 

 

 

0

0

 

 

details

Array

 

 

0

 

 

 

 

 

Scheduled Task fields See Common Data Fields - Scheduled Task fields for details of all fields in the Schedule Info, Progress Info and Resources sections of the property sheet.                    
Attachments

Click the button to display the Attachments Editor, used to attach and manage photos, sketches and other files associated with the network object.

In the case of acoustic surveys, the native SewerBatt file (.mat format), if present, will appear as an attachment if it was present in the same directory as the XML file at survey import time.

See Attachments Editor and Common Data Fields for further details.

attachments Array                
General properties fields See Common Data Fields for details of field in the General properties section of the property sheet.                    
User defined properties fields See Common Data Fields - User Fields for details of fields in the User defined properties section of the property sheet.                    

Renaming Additional User Fields

Survey Grid

Creating an Acoustic Survey

Network Data Fields