Pipe Repair Data Fields (Collection)
Pipe repair data can be edited on either the Pipe Repair Grid Window of the Repair Grid or the Pipe Repair Property Sheet.
To view and edit all pipe repair data, use the Property Sheet.
The following describes all the data which can be used to define a pipe repair.
Fields that are common to the majority of objects can be found in the Common Fields topic.
Pipe Repair Data
Database Table Name: cams_pipe_repair
Field Name |
Help Text |
Database Field |
Size |
Precision |
Default |
Error Lower Limit |
Error Upper Limit |
Warning Lower Limit |
Warning Upper Limit |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ID |
Unique identifier for the repair. |
id |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Repair type |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
repair_type |
Text |
20 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Defect type |
The type of defect requiring repair:
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
defect_type |
Text |
15 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Status |
The current status of the repair in relation to completion:
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
status |
Text |
32 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Cause of failure |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
cause_of_failure |
Text |
40 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Start length |
Location along pipe where repair starts, relative to upstream end of pipe. Default is 0. |
start_length |
Double |
|
L |
3 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Repair length |
Length of pipe repaired. Default is calculated as Length of pipe with which repair is associated minus Start Length of repair. |
repair_length |
Double |
|
L |
3 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Location |
Address or description of site at which asset is located. |
location |
Text |
100 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
CCTV survey ID (before) |
ID of CCTV survey used to identify the requirement for the pipe repair. This field will be automatically populated when creating a pipe repair as a scheduled task for the CCTV survey. |
cctv_survey_id | Text | 40 | 0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
CCTV required |
Check this box if a review CCTV survey is required to verify that the pipe repair has been carried out correctly. The repair will not be automatically closed when updating scheduled tasks if a completed review CCTV survey does not exist. |
cctv_required | Boolean | 0 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Review CCTV survey ID (after) |
ID of CCTV survey used to verify that the repair has been carried out correctly. This field will be automatically populated when creating a CCTV survey as a scheduled task for the pipe repair. |
review_cctv_survey_id | Text | 40 | 0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
US node ID |
ID of the node upstream of the associated pipe. |
us_node_id |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DS node ID |
ID of the node downstream of the associated pipe. |
ds_node_id |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Link suffix |
Suffix of the associated pipe. |
link_suffix |
Text |
1 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
PLR / asset ID | Pipe reference code. | plr | Text | 40 | 0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Connection pipe ID |
ID of the associated connection pipe. |
connection_pipe_id | Text | 40 | 0 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Job number |
Job reference number. |
job_number |
Text |
15 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Material |
The options available in the dropdown list depend on which coding standard is being used. See the Standards and Choice Lists dialog for further information. |
material |
Text |
64 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Lining material |
The options available in the dropdown list depend on which coding standard is being used. See the Standards and Choice Lists dialog for further information. |
lining_material |
Text |
64 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Lining type |
The options available in the dropdown list depend on which coding standard is being used. See the Standards and Choice Lists dialog for further information. |
lining_type |
Text |
64 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Shape |
The options available in the dropdown list depend on which coding standard is being used. See the Standards and Choice Lists dialog for further information. |
shape |
Text |
15 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Width |
Repaired pipe dimension. |
width |
Double |
|
CAMS_PS |
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Height |
Repaired pipe dimension. |
height |
Double |
|
CAMS_PS |
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Scheduled Task fields | See Common Data Fields - Scheduled Task fields for details of all fields in the Schedule Info, Progress Info and Resources sections of the property sheet. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Attachments |
Click the button to display the Attachments Editor, used to attach and manage photos, sketches and other files associated with the network object. See Attachments Editor and Common Data Fields for further details. |
attachments | Array | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
General properties fields | See Common Data Fields for details of field in the General properties section of the property sheet. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
User defined properties fields | See Common Data Fields - User Fields for details of fields in the User defined properties section of the property sheet. |