User Defined Ancillary Data Fields
User Defined Ancillary data can be edited on either the User Ancillary Grid Window of the Asset Grid or the User Ancillary Property Sheet.
To view and edit all user defined ancillary data, use the Property Sheet.
The following describes all the data which can be used to define a user defined ancillary.
Fields that are common to the majority of objects can be found in the Common Fields topic.
User Defined Ancillary Data
Database Table Name: cams_ancillary
Field Name |
Help Text |
Database Field |
Size |
Precision |
Default |
Error Lower Limit |
Error Upper Limit |
Warning Lower Limit |
Warning Upper Limit |
||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ID |
The name of the object. The ID is the primary key in the database for the network object. This means that the ID field of each object must be unique for all objects of the same object type. |
id |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||
US node ID |
Upstream node. |
us_node_id |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||
DS node ID |
Downstream node. |
ds_node_id |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||
Owner |
The proprietor of the asset. |
owner |
Text |
64 |
|
0 |
|
|
|
|
|
||||||||||||||
System type |
System type:
The options available in the dropdown list depend on which coding standard is being used. See the Standards and Choice Lists dialog for further information. |
system_type |
Text |
10 |
|
0 |
|
|
|
|
|
||||||||||||||
Type |
The type of ancillary structure:
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
type |
Text |
10 |
|
0 |
|
|
|
|
|
||||||||||||||
Operational status |
Current operational status:
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
status |
Text |
10 |
|
1 |
|
|
|
|
|
||||||||||||||
X coord |
X coordinate of the object. |
x |
Double |
|
XY |
2 |
|
|
|
|
|
||||||||||||||
Y coord |
Y coordinate of the object. |
y |
Double |
|
XY |
2 |
|
|
|
|
|
||||||||||||||
Branch ID |
Numeric field used to identify to which long section the link is associated. (See Defining Branches for further information.) |
branch_id |
|
|
0 |
|
|
|
|
|
|||||||||||||||
Condition grade |
A measure of asset condition for ancillary assets. By analogy with pipe condition grades, this is usually a number in the range 1-5. Unlike pipe condition grade, there is no distinction between structural and service condition for ancillary assets. |
condition_grade |
|
|
0 |
|
|
|
|
|
|||||||||||||||
Critical |
A measure of the likely impact of asset failure. The WRC SRM uses the codes A, B, C to represent "A" sewers where failures would be expensive to "C" where failures would be relatively cheap. |
criticality |
Text |
5 |
|
0 |
|
|
|
|
|
||||||||||||||
Security |
The security of the asset from unauthorised access/tampering:
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
security |
Text |
10 |
|
0 |
|
|
|
|
|
||||||||||||||
Construction date |
Construction or installation date. This is date from which depreciation costs will be incurred for depreciation reports. |
constr_date |
|
|
0 |
|
|
|
|
|
|||||||||||||||
Condition survey date |
Date of the most recent condition survey of the asset. |
survey_date |
|
|
0 |
|
|
|
|
|
|||||||||||||||
Installation cost |
The original installation cost of the asset. This generally includes all costs incurred (e.g. mantime, asset purchase costs etc). This information is used in depreciation reports. |
install_cost |
Double |
|
WN_COST |
2 |
|
|
|
|
|
||||||||||||||
Replacement cost |
The estimated cost for completely replacing an asset. |
replace_cost |
Double |
|
WN_COST |
2 |
|
|
|
|
|
||||||||||||||
Rehabilitation Cost |
Rehabilitation costs to be incurred in bringing the asset to an acceptable condition. This is used in rehabilitation reports. |
rehab_cost |
Double |
|
WN_COST |
2 |
|
|
|
|
|
||||||||||||||
Inspection cost |
Estimated cost of asset inspection. |
inspection_cost |
Double |
|
WN_COST |
2 |
|
|
|
|
|
||||||||||||||
Expected lifetime |
The expected lifetime of the asset. This is used in depreciation reports as the period over which installation costs may be depreciated. |
lifetime |
|
|
0 |
|
|
|
|
|
|||||||||||||||
Width |
The width of the ancillary object. |
width |
Double |
|
MANH_DIM |
1 |
|
|
|
|
|
||||||||||||||
Level |
The level or height of the ancillary object. |
level |
Double |
|
Z |
1 |
|
|
|
|
|
||||||||||||||
Attachments |
Click the button to display the Attachments Editor, used to attach and manage photos, sketches and other files associated with the network object. See Attachments Editor and Common Data Fields for further details. |
attachments | Array | ||||||||||||||||||||||
General properties fields | See Common Data Fields for details of field in the General properties section of the property sheet. | ||||||||||||||||||||||||
User defined properties fields | See Common Data Fields - User Fields for details of fields in the User defined properties section of the property sheet. | ||||||||||||||||||||||||
Time series links |
Click the button to display the Time Series Data Source Grid, which is used to specify or update the time series data streams that are linked to this network object. |
tsdb_links |