Bridge Outlet Data Fields
Bridge Outlet data can be edited on either the Bridge Outlet Grid Window of the Links Grid or the Bridge Outlet Property Sheet.
To view and edit all bridge outlet data, use the Property Sheet.
This table describes all the bridge outlet specific data which can be used to define a bridge outlet.
Fields that are common to the majority of objects can be found in the Common Fields topic.
Bridge Outlet Data
Database Table Name: hw_bridge_outlet
Show Columns |
Database Names |
Size, Type and Units |
|
Defaults and Error Limits |
Field Name |
Help Text |
Database Field |
Size |
Precision |
Default |
Error Lower Limit |
Error Upper Limit |
Warning Lower Limit |
Warning Upper Limit |
|||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ID | Unique identifier for the bridge outlet | id | Text | 64 | 0 | |||||||||||||||||||||||||||
Bridge US node ID | Upstream node ID of bridge to which the outlet is associated. | bridge_us_node_id | Text | 64 | 0 | |||||||||||||||||||||||||||
Bridge link suffix | Link suffix of bridge to which the outlet is associated. | bridge_link_suffix | Text | 1 | 0 | 1 | ||||||||||||||||||||||||||
Asset ID | For reference only. Designed as a reference to an asset database, but could be used for anything. | asset_id | Text | 64 | 0 | |||||||||||||||||||||||||||
System type |
Choose the system type from the dropdown list. See System Type for more information.
|
system_type | Text | 10 | 0 | Other | ||||||||||||||||||||||||||
Invert level | Invert level measured above system datum | invert | Double | Z | 3 | -9999 | 9999 | 6000 | ||||||||||||||||||||||||
Reverse flow model |
Determines how the engine models reverse flow: either as a nominal headloss or by using the culvert inlet model.
|
reverse_flow_model | Text | 8 | 0 | Nominal | ||||||||||||||||||||||||||
Equation |
Equation as defined in CIRIA Funders Report/CP/40, used to calculate the water level immediately upstream of the inlet.
|
equation | Text | 1 | 0 | A | ||||||||||||||||||||||||||
K | Equation constant as defined in CIRIA Funders Report/CP/40. | k | Double | 4 | 0.0001 | |||||||||||||||||||||||||||
M | Equation constant as defined in CIRIA Funders Report/CP/40. | m | Double | 3 | 0.01 | |||||||||||||||||||||||||||
c | Equation constant as defined in CIRIA Funders Report/CP/40. | c | Double | 4 | 0.01 | |||||||||||||||||||||||||||
Y | Equation constant as defined in CIRIA Funders Report/CP/40. | y | Double | 2 | 0.01 | |||||||||||||||||||||||||||
Outlet headloss coefficient (Ko) |
Outlet Headloss Coefficient, usually 1.0. (CIRIA Funders Report/CP/40) |
headloss_coeff | Double | 2 | 1 | 0.01 | ||||||||||||||||||||||||||
Inlet headloss coefficient (Ki) | Constant as defined in CIRIA Funders Report/CP/40. | inlet_headloss_coeff | Double | 2 | 0.01 |