Connection Pipe Data
Database Table Name: cams_connection_pipe
Field Name |
Help Text |
Database Field |
Size |
Precision |
Default |
Error Lower Limit |
Error Upper Limit |
Warning Lower Limit |
Warning Upper Limit |
||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Connection pipe ID | A unique identifier for the connection pipe. | id | Text | 40 | 0 | ||||||||||||||||||||
US node ID |
ID of node to which upstream end of pipe is connected. |
us_node_id |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||
DS node ID |
ID of node to which downstream end of pipe is connected. |
ds_node_id |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||
Property ID | ID of property from which pipe is connected. | property_id | Text | 40 | 0 | ||||||||||||||||||||
Asset ID |
An optional reference - usually the asset database name for this network object (if applicable). |
asset_id |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||
Description | Additional information. | description | Text | 100 | 0 | ||||||||||||||||||||
Owner |
The proprietor of the asset. |
owner |
Text |
64 |
|
0 |
|
|
|
|
|
||||||||||||||
Location |
Address or description of site at which asset is located. |
location |
Text |
100 |
|
0 |
|
|
|
|
|
||||||||||||||
System type / use |
System type:
Choices available depend on the CCTV Standard being used. |
system_type |
Text |
10 |
|
0 |
|
|
|
|
|
||||||||||||||
Operational status |
The current operational status:
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
status |
Text |
10 |
|
1 |
|
|
|
|
|
||||||||||||||
Type |
Type of connection:
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
type |
Text |
10 |
|
0 |
|
|
|
|
|
||||||||||||||
Branch ID |
Numeric field used to identify to which long section the link is associated. (See Defining Branches for further information). |
branch_id |
Long Integer |
|
|
0 |
|
|
|
|
|
||||||||||||||
X start | X coordinate at upstream end of pipe. | x_start | Double | XY | 2 | ||||||||||||||||||||
Y start | Y coordinate at upstream end of pipe. | y_start | Double | XY | 2 | ||||||||||||||||||||
Z start | Elevation at upstream end of pipe. | z_start | Double | Z | 2 | ||||||||||||||||||||
X end | X coordinate at downstream end of pipe. | x_end | Double | XY | 2 | ||||||||||||||||||||
Y end | Y coordinate at downstream end of pipe. | y_end | Double | XY | 2 | ||||||||||||||||||||
Z end | Elevation at downstream end of pipe. | z_end | Double | Z | 2 | ||||||||||||||||||||
Shape ID |
Cross-sectional shape of pipe. Choices available depend on the CCTV Standard being used. |
shape |
Text |
10 |
|
0 |
|
|
|
|
|
||||||||||||||
Diameter | Diameter of pipe. | diameter | Double | CAMS_PS | 0 | 0 | |||||||||||||||||||
Pipe length |
Pipe Length. |
length |
Double |
|
L |
3 |
|
|
|
|
|
||||||||||||||
Pipe material |
Material of pipe. Choices available depend on the CCTV Standard being used. |
pipe_material | Text | 64 | 0 | ||||||||||||||||||||
Lining material |
Material of pipe lining. Choices available depend on the CCTV Standard being used. |
pipe_lining_type | Text | 10 | |||||||||||||||||||||
Lining type |
Type of lining. Choices available depend on the CCTV Standard being used. |
lining_material | Text | 10 | |||||||||||||||||||||
Date installed |
Date of pipe installation. |
year_laid |
Date / Time |
|
|
0 |
|
|
|
|
|
||||||||||||||
Year renewed |
Year of pipe renewal. |
year_renew |
Date / Time |
|
|
0 |
|
|
|
|
|
||||||||||||||
Ground level | Ground level at pipe location. | ground_level | Double | Z | 3 | -99.99 | 999.99 | ||||||||||||||||||
Condition code | Indication of asset condition. | condition_code | Text | 8 | 0 | ||||||||||||||||||||
Critical / strategic sewer category | A measure of the likely impact of asset failure. The WRC SRM uses the codes A, B, C to represent "A" sewers where failures would be expensive to "C" where failures would be relatively cheap. | criticality | Text | 5 | 0 | ||||||||||||||||||||
Service condition grade |
Service condition index calculated according to the chosen CCTV scoring scheme. May be updated automatically from CCTV Survey Data. |
service_condition_score |
Long Integer |
|
|
0 |
|
|
|
|
|
||||||||||||||
Structural condition grade |
Structural condition index calculated according to the chosen CCTV scoring scheme. May be updated automatically from CCTV Survey Data. |
condition_score |
Long Integer |
|
|
0 |
|
|
|
|
|
||||||||||||||
Internal grade |
Pipe condition index field available when using the CH2M HILL SCREAM™ CCTV scoring scheme. May be updated automatically from CCTV Survey Data. |
internal_pipe_score |
Long Integer |
|
|
0 |
|
|
|
|
|
||||||||||||||
Condition survey date |
Date of the most recent condition survey of the asset. |
survey_date |
Date / Time |
|
|
0 |
|
|
|
|
|
||||||||||||||
Date cleaned |
The date the asset last underwent maintenance to improve performance (swabbing, scouring). |
date_cleaned |
Date / Time |
|
|
0 |
|
|
|
|
|
||||||||||||||
Maintenance score |
Maintenance Defect Score field available when using the CH2M HILL SCREAM™ CCTV scoring scheme. May be updated automatically from CCTV Survey Data. |
int_pipe_CH2MHill_maint_scr |
Long Integer |
|
|
0 |
|
|
|
|
|
||||||||||||||
Structural score |
Structural Defect Score field available when using the CH2M HILL SCREAM™ CCTV scoring scheme. May be updated automatically from CCTV Survey Data. |
int_pipe_CH2MHill_struc_scr |
Long Integer |
|
|
0 |
|
|
|
|
|
||||||||||||||
Internal score |
Pipe Internal Score field available when using the CH2M HILL SCREAM™ CCTV scoring scheme. May be updated automatically from CCTV Survey Data. |
int_pipe_CH2MHill_scr |
Long Integer |
|
|
0 |
|
|
|
|
|
||||||||||||||
Rehabilitation cost |
Rehabilitation costs to be incurred in bringing the asset to an acceptable condition. This is used in rehabilitation reports |
rehab_cost |
Double |
|
WN_COST |
2 |
|
|
|
|
|
||||||||||||||
Installation cost |
The original installation cost of the asset. This generally includes all costs incurred (e.g. mantime, asset purchase costs etc). This information is used in depreciation reports |
install_cost |
Double |
|
WN_COST |
2 |
|
|
|
|
|
||||||||||||||
Replacement cost |
The estimated cost for completely replacing an asset. |
replace_cost |
Double |
|
WN_COST |
2 |
|
|
|
|
|
||||||||||||||
Expected lifetime |
The expected lifetime of the asset. This is used in depreciation reports as the period over which installation costs may be depreciated. |
lifetime |
Long Integer |
|
|
0 |
|
|
|
|
|
||||||||||||||
Inspection cost |
Estimated cost of asset inspection. |
inspection_cost |
Double |
|
WN_COST |
2 |
|
|
|
|
|
||||||||||||||
Current value |
Current value of the asset. This gives an indication of depreciation costs as depreciation cost = installation cost - current value. |
current_value |
Double |
|
WN_COST |
2 |
|
|
|
|
|
||||||||||||||
Name groups | Click the button to display the Name Groups Editor, used to view and edit the Asset Name Groups to which the object belongs. | ||||||||||||||||||||||||
Attachments |
Click the button to display the Attachments Editor, used to attach and manage photos, sketches and other files associated with the network object. See Attachments Editor and Common Data Fields for further details. |
attachments | Array | ||||||||||||||||||||||
General properties data fields | See Common Data Fields for details of field in the General properties section of the property sheet. | ||||||||||||||||||||||||
User defined properties data fields | See Common Data Fields - User Fields for details of fields in the User defined properties section of the property sheet. | ||||||||||||||||||||||||
Time series links |
Click the button to display the Time Series Data Source Grid, which is used to specify or update the time series data streams that are linked to this channel. |
tsdb_links |
|
|
|
|