Pump (Collection) Data Fields
Pump data can be edited on either the Pump Grid Window of the Asset Grid or the Pump Property Sheet.
To view and edit all pump data, use the Property Sheet.
The following describes all the data which can be used to define a pump.
Fields that are common to the majority of objects can be found in the Common Fields topic.
Pump Data
Database Table Name: cams_pump
Field Name |
Help Text |
Database Field |
Size |
Precision |
Default |
Error Lower Limit |
Error Upper Limit |
Warning Lower Limit |
Warning Upper Limit |
||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ID |
The name of the object. The ID is the primary key in the database for the network object. This means that the ID field of each object must be unique for all objects of the same object type. |
id |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||
US node ID |
Upstream node. |
us_node_id |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||
DS node ID |
Downstream node. |
ds_node_id |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||
Owner |
The proprietor of the asset. |
owner |
Text |
64 |
|
0 |
|
|
|
|
|
||||||||||||||
System type |
System type:
The options available in the dropdown list depend on which coding standard is being used. See the Standards and Choice Lists dialog for further information. |
system_type |
Text |
10 |
|
0 |
|
|
|
|
|
||||||||||||||
Type |
The type of ancillary structure.
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
type |
Text |
10 |
|
0 |
|
|
|
|
|
||||||||||||||
Operational status |
Current operational status:
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
status |
Text |
10 |
|
1 |
|
|
|
|
|
||||||||||||||
Pump station ID | ID of pump station where the pump is located. | pump_station_id | Text | 40 | 0 | ||||||||||||||||||||
Treatment works ID | ID of the treatment works where the pump is located. | pump_station_id | Text | 40 | 0 | ||||||||||||||||||||
Pump group |
Pump group in the associated pumping station to which the pump belongs. Pump group details are stored in the pumping station object. |
pump_group | Text | 40 | 0 | ||||||||||||||||||||
X Coord |
X coordinate of the object. |
x |
Double |
|
XY |
2 |
|
|
|
|
|
||||||||||||||
Y Coord |
Y coordinate of the object. |
y |
Double |
|
XY |
2 |
|
|
|
|
|
||||||||||||||
Branch ID |
Numeric field used to identify to which long section the link is associated. (See Defining Branches for further information). |
branch_id |
Long Integer |
|
|
0 |
|
|
|
|
|
||||||||||||||
Make |
Pump make or manufacturer. |
make |
Text |
30 |
|
1 |
|
|
|
|
|
||||||||||||||
Model |
Pump model number. |
model |
Text |
30 |
|
1 |
|
|
|
|
|
||||||||||||||
Serial No |
Pump serial number. |
serial_no |
Text |
30 |
|
1 |
|
|
|
|
|
||||||||||||||
Capacity |
Rated discharge of pump. |
capacity |
Double |
|
|
1 |
|
|
|
|
|
||||||||||||||
Switch on level |
The upstream level at which the pump operates. |
level_on |
Double |
|
Z |
3 |
|
|
|
|
|
||||||||||||||
Switch off level |
The upstream level at which the pump ceases operation. |
level_off |
Double |
|
Z |
3 |
|
|
|
|
|
||||||||||||||
Delay |
The run-up time before the pump is operational at its design discharge. |
delay |
Double |
|
TS |
1 |
|
|
|
|
|
||||||||||||||
Discharge |
Rate of flow delivered by pump. |
discharge |
Double |
|
Q |
3 |
|
|
|
|
|
||||||||||||||
Suction diameter | Suction (inlet) diameter of the pump. | suction_diameter | Double | CAMS_PS | 0 | ||||||||||||||||||||
Pressure diameter | Pressure (outlet) diameter of the pump. | pressure_diameter | Double | CAMS_PS | 0 | ||||||||||||||||||||
Nominal speed | Rated speed from manufacturers documentation. | nominal_speed | Double | WN_AV | 0 | ||||||||||||||||||||
Nominal flow | Rated flow from manufacturers documentation. | nominal_flow | Double | IN_Q | 2 | ||||||||||||||||||||
Nominal head | Rated head from manufacturers documentation. | nominal_head | Double | WN_P | 2 | ||||||||||||||||||||
Pump impeller | Type of impeller. | pump_impeller | Text | 40 | |||||||||||||||||||||
Manhole | Manhole at which pump is located. | manhole_id | Text | 40 | 0 | ||||||||||||||||||||
Number of stages | Number of pump stages for multi-stage pumps. | num_stages | Long Integer | 0 | |||||||||||||||||||||
Date serviced | Date pump was last serviced. | date_serviced | Date / Time | 0 | |||||||||||||||||||||
Control mechanism |
Method by which pump state is controlled:
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
control | Text | 10 | 0 | ||||||||||||||||||||
Power | Power rating of pump. | power | Double | WN_POW | 2 | ||||||||||||||||||||
Head discharge ID |
The identifier of the head discharge table used by the pump. Head discharge objects are defined on the Head discharge tab of the Asset Grid. A new head discharge object can also be added using the button, located to the left of the Head discharge ID field. This displays the Insert New Head discharge Object option that allows you to add the new object. |
head_discharge_id | Text | 64 | 0 | ||||||||||||||||||||
Motor type | Type of motor. | motor_type | Text | 40 | |||||||||||||||||||||
Motor manufacturer | The name of the company who fabricated the asset. | motor_manufacturer | Text | 40 | |||||||||||||||||||||
Motor model | Model number of the pump motor. | motor_model | Text | 40 | |||||||||||||||||||||
Motor serial number | Serial number of pump motor. | motor_serial_number | Text | 30 | 0 | ||||||||||||||||||||
Motor capacity | Capacity of the pump motor. | motor_capacity | Text | 40 | |||||||||||||||||||||
Date motor installed | The date of installation of the pump motor. | date_motor_installed | Date / Time | 0 | |||||||||||||||||||||
Condition Grade |
A measure of asset condition for ancillary assets. By analogy with pipe condition grades, this is usually a number in the range 1-5. Unlike pipe condition grade, there is no distinction between structural and service condition for ancillary assets. |
condition_grade |
Long Integer |
|
|
0 |
|
|
|
|
|
||||||||||||||
Critical |
A measure of the likely impact of asset failure. The WRC SRM uses the codes A, B, C to represent "A" sewers where failures would be expensive to "C" where failures would be relatively cheap. |
criticality |
Text |
5 |
|
0 |
|
|
|
|
|
||||||||||||||
Security |
The security of the asset from unauthorised access/tampering:
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
security |
Text |
10 |
|
0 |
|
|
|
|
|
||||||||||||||
Construction date |
Construction or installation date. This is date from which depreciation costs will be incurred for depreciation reports. |
constr_date |
Date / Time |
|
|
0 |
|
|
|
|
|
||||||||||||||
Condition survey date |
Date of the most recent condition survey of the asset. |
survey_date |
Date / Time |
|
|
0 |
|
|
|
|
|
||||||||||||||
Installation cost |
The original installation cost of the asset. This generally includes all costs incurred (e.g. mantime, asset purchase costs etc). This information is used in depreciation reports |
install_cost |
Double |
|
WN_COST |
2 |
|
|
|
|
|
||||||||||||||
Inspection cost |
Estimated cost of asset inspection |
inspection_cost |
Double |
|
WN_COST |
2 |
|
|
|
|
|
||||||||||||||
Expected lifetime |
The expected lifetime of the asset. This is used in depreciation reports as the period over which installation costs may be depreciated. |
lifetime |
Long Integer |
|
|
0 |
|
|
|
|
|
||||||||||||||
Rehabilitation cost |
Rehabilitation costs to be incurred in bringing the asset to an acceptable condition. This is used in rehabilitation reports. |
rehab_cost |
Double |
|
WN_COST |
2 |
|
|
|
|
|
||||||||||||||
Replacement cost |
The estimated cost for completely replacing an asset. |
replace_cost |
Double |
|
WN_COST |
2 |
|
|
|
|
|
||||||||||||||
Attachments |
Click the button to display the Attachments Editor, used to attach and manage photos, sketches and other files associated with the network object. See Attachments Editor and Common Data Fields for further details. |
attachments | Array | ||||||||||||||||||||||
General properties data fields | See Common Data Fields for details of field in the General properties section of the property sheet. | ||||||||||||||||||||||||
User defined properties data fields | See Common Data Fields - User Fields for details of fields in the User defined properties section of the property sheet. | ||||||||||||||||||||||||
Time series links |
Click the button to display the Time Series Data Source Grid, which is used to specify or update the time series data streams that are linked to this pump. |
tsdb_links |