Node Data Fields
Information relating to a node can be viewed and edited on the Node Grid Window of the Asset Grid or on the Node Property Sheet.
The diagram below illustrates how the InfoAsset Manager Manhole Dimensions fields relate to a manhole cross-section.
If you are using the EU manhole standard, you can choose to have a streamlined version of the node Property Window containing only the fields relevant to this standard (Refer to Standards and Choice Lists Dialog topic for further details). In this case, please note that the layout of some tabs (mainly Cover, Interior and Condition) may not contain all the fields described below and that some other tabs such as Cover 2 and Interior 2 may not exist.
Node Data
Database Table Name: cams_manhole
Field Name |
Help Text |
Database Field |
Size |
Precision |
Default |
Error Lower Limit |
Error Upper Limit |
Warning Lower Limit |
Warning Upper Limit |
||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ID |
A unique name for the manhole, up to 40 letters, numbers and underscore characters. Upper and lower case letters are treated as being the same. |
node_id |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Asset ID |
An optional reference - usually the asset database name for this network object (if applicable). |
asset_id |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Location |
Address or description of site at which asset is located. |
location |
Text |
100 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
System type |
The options available in the list depend on which Manhole coding standard is being used for this network. See the Standards and Choice Lists dialog for further information. |
system_type |
Text |
10 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Date installed |
Date of installation. |
year_laid |
Date / Time |
|
|
1 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Year renewed |
Year sewer was renewed. |
year_renewed |
Long Integer |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Ground level |
Height above datum of ground surface. |
ground_level |
Double |
|
Z |
3 |
|
|
|
-99.99 |
999.99 |
||||||||||||||||||||||||||||||||||||||||||||
Drainage code |
Drainage area code. |
drainage_code |
Text |
10 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Drainage area |
MACP Coding Standard field Drainage area name. |
drainage_area |
Text |
15 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
X coordinate |
X coordinate of the object. |
x |
Double |
|
XY |
2 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Y coordinate |
Y coordinate of the object. |
y |
Double |
|
XY |
2 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Type |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
node_type |
Text |
10 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Status |
The current status of the manhole:
The options available in the dropdown list depend on which coding standard is being used. See the Standards and Choice Lists dialog for further information. |
status |
Text |
10 |
|
1 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Street |
MACP Coding Standard field Manhole location description. |
street |
Text |
64 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
City |
MACP Coding Standard field Location of manhole. |
city |
Text |
64 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Coordinate system |
MACP Coding Standard field System used for GPS coordinates. |
coordinate_system |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Location details |
MACP Coding Standard field Manhole location description. |
location_details |
Text |
255 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Access type |
MACP Coding Standard field |
access_type |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Location code |
MACP Coding Standard field Ground cover description. |
location_code |
Text |
30 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Owner |
The proprietor of the asset. |
owner |
Text |
64 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Site managed by |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
site_managed_by |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
PO number |
MACP Coding Standard field Customer purchase order number. |
po_number | Text | 15 | 0 | 0 | 0 | 0 | 0 | ||||||||||||||||||||||||||||||||||||||||||||||
Inspection status |
MACP Coding Standard field |
inspection_status |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Category |
MACP Coding Standard field Indicates importance of sewer. |
category |
Text |
2 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Structural condition |
A measure of asset condition for ancillary assets. By analogy with pipe condition grades, this is usually a number in the range 1-5. Unlike pipe condition grade, there is no distinction between structural and service condition for ancillary assets. |
condition_grade |
Long Integer |
|
|
0 |
|
|
|
0 |
5 |
||||||||||||||||||||||||||||||||||||||||||||
Shaft condition |
A measure of asset condition. Usually a number in the range 1-5. |
shaft_condition |
Long Integer |
|
|
0 |
|
|
|
0 |
5 |
||||||||||||||||||||||||||||||||||||||||||||
Cover condition |
A measure of asset condition. Usually a number in the range 1-5. |
cover_condition |
Long Integer |
|
|
0 |
|
|
|
0 |
5 |
||||||||||||||||||||||||||||||||||||||||||||
Maintenance condition |
A measure of asset condition. Usually a number in the range 1-5. |
maintenance_condition |
Long Integer |
|
|
0 |
|
|
|
0 |
5 |
||||||||||||||||||||||||||||||||||||||||||||
Chamber condition |
A measure of asset condition. Usually a number in the range 1-5. |
chamber_condition |
Long Integer |
|
|
0 |
|
|
|
0 |
5 |
||||||||||||||||||||||||||||||||||||||||||||
Leveler condition |
A measure of asset condition. Usually a number in the range 1-5. |
leveler_condition |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Site condition |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
site_condition |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Depth of flow |
Depth of flow in manhole. |
flow_depth |
Double |
|
MANH_Y |
0 |
|
|
|
0 |
9999 |
||||||||||||||||||||||||||||||||||||||||||||
Silt depth |
Depth of silt in manhole. |
silt_depth |
Double |
|
MANH_Y |
0 |
|
|
|
0 |
9999 |
||||||||||||||||||||||||||||||||||||||||||||
Surcharge height |
Surcharge height in manhole. |
surcharge_height |
Double |
|
MANH_Y |
0 |
|
|
|
0 |
9999 |
||||||||||||||||||||||||||||||||||||||||||||
Survey date |
Date of the most recent condition survey of the asset. |
survey_date |
Date / Time |
|
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
GPS survey date |
The date of the most recent GPS survey (DD/MM/YYYY). |
gps_survey_date |
Date / Time |
|
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Critical |
A measure of the likely impact of asset failure. The WRC SRM uses the codes A, B, C to represent "A" sewers where failures would be expensive to "C" where failures would be relatively cheap. |
criticality |
Text |
5 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Security |
The security of the asset from unauthorised access/tampering:
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
security |
Text |
10 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Gas type |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
gas_type |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Attend to cover |
Check box indicating whether manhole cover requires repair. |
attend_to_cover |
Boolean |
|
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Attend to step |
Check box indicating whether manhole steps require repair. |
attend_to_step |
Boolean |
|
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Attend to shaft |
Check box indicating whether manhole shaft requires repair. |
attend_to_shaft |
Boolean |
|
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Attend to chamber |
Check box indicating whether manhole chamber requires repair. |
attend_to_chamber |
Boolean |
|
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Attend to bench |
Check box indicating whether manhole bench requires repair. |
attend_to_bench |
Boolean |
|
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Attend to other |
Check box indicating whether repair is required to area not already specified. |
attend_to_other |
Boolean |
|
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Toxic atmosphere |
Check box indicating whether there are hazardous gases in the atmosphere. |
toxic_atmosphere |
Boolean |
|
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Evidence of vermin |
Check box indicating whether the presence of vermin has been detected. |
vermin |
Boolean |
|
|
3 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Overall infiltration/ inflow grade |
Overall Infiltration/Inflow grade using the CH2M HILL SCREAM™ manhole scoring standard. May be updated automatically from Manhole Survey Data. |
CH2MHill_overall_ii_grade |
Long Integer |
|
|
0 |
|
|
|
0 |
5 |
||||||||||||||||||||||||||||||||||||||||||||
Overall structural and infiltration/ inflow grade |
Overall Structural and Infiltration/Inflow grade using the CH2M HILL SCREAM™ manhole scoring standard. May be updated automatically from Manhole Survey Data. |
CH2MHill_overall_sii_grade |
Long Integer |
|
|
0 |
|
|
|
0 |
5 |
||||||||||||||||||||||||||||||||||||||||||||
Overall total grade |
Overall Total grade using the CH2M HILL SCREAM™ manhole scoring standard. May be updated automatically from Manhole Survey Data. |
CH2MHill_overall_total_grad |
Long Integer |
|
|
0 |
|
|
|
0 |
5 |
||||||||||||||||||||||||||||||||||||||||||||
Cover shape |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
cover_shape |
Text |
10 |
|
1 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Cover duty |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
cover_duty |
Text |
10 |
|
1 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Cover material |
The options available in the list depend on which coding standard is being used for this network. See the Standards and Choice Lists dialog for further information. |
cover_material |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Hole diameter |
MACP Coding Standard field |
hole_diameter |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Hole number |
MACP Coding Standard field |
hole_number |
Long Integer |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cover dimension |
Size of manhole cover. |
cover_dim |
Double |
|
MANH_DIM |
0 |
|
|
|
0 |
9999 |
||||||||||||||||||||||||||||||||||||||||||||
Cover dimension 2 |
Size of manhole cover. |
cover_dim_2 |
Double |
|
MANH_DIM |
0 |
|
|
|
0 |
9999 |
||||||||||||||||||||||||||||||||||||||||||||
Cover level |
Height above datum of manhole cover. |
cover_level |
Double |
|
Z |
3 |
|
|
|
-99.99 |
999.99 |
||||||||||||||||||||||||||||||||||||||||||||
Cover assembly |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
cover_assembly |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Cover frame fit |
MACP Coding Standard field |
cover_frame_fit |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cover bearing surface diameter |
MACP Coding Standard field |
cover_bearing_surface_dia |
Double |
|
MANH_DIM |
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cover bearing surface diameter width |
MACP Coding Standard field |
cover_bearing_surface_dia_width |
Double |
|
MANH_DIM |
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cover hinged |
Check box indicating whether manhole cover is hinged. |
cover_hinged |
Boolean |
|
|
1 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Cover locked |
Check box indicating whether manhole cover is locked. |
cover_locked |
Boolean |
|
|
1 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Side entry |
Check box indicating whether the manhole is a side entry manhole. |
side_entry |
Boolean |
|
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Cover type solid |
MACP Coding Standard field |
cover_type_solid |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cover type vented |
MACP Coding Standard field |
cover_type_vented |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cover type gasketed |
MACP Coding Standard field |
cover_type_gasketed |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cover type bolted |
MACP Coding Standard field |
cover_type_bolted |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cover type inner cover |
MACP Coding Standard field |
cover_type_inner_cover |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cover type locking |
MACP Coding Standard field |
cover_type_locking |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cover type lamphole | MACP Coding Standard field | cover_type_lamphole | Boolean | 0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
Cover type hatch single | MACP Coding Standard field | cover_type_hatch_single | Boolean | 0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
Cover type hatch double | MACP Coding Standard field | cover_type_hatch_double | Boolean | 0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
Cover condition sound |
MACP Coding Standard field |
cover_condition_sound |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cover condition cracked |
MACP Coding Standard field |
cover_condition_cracked |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cover condition broken |
MACP Coding Standard field |
cover_condition_broken |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cover condition corroded |
MACP Coding Standard field |
cover_condition_corroded |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cover condition bolts missing |
MACP Coding Standard field |
cover_condition_boltsmissing |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cover condition missing |
MACP Coding Standard field |
cover_condition_missing |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cover condition restraint missing | MACP Coding Standard field | cover_condition_restraint_miss | Boolean | 0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
Cover condition restraint defective | MACP Coding Standard field | cover_condition_restraint_defect | Boolean | 0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
Cover insert type |
MACP Coding Standard field |
cover_insert_type |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Insert condition sound |
MACP Coding Standard field |
insert_condition_sound |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Insert condition poorly fitting |
MACP Coding Standard field |
insert_condition_poorlyfitting |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Insert condition cracked |
MACP Coding Standard field |
insert_condition_cracked |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Insert condition leaking |
MACP Coding Standard field |
insert_condition_leaking |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Insert condition insert fell |
MACP Coding Standard field |
insert_condition_insertfell |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Insert condition corroded | MACP Coding Standard field | insert_condition_corroded | Boolean | 0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
Adjustment ring type |
MACP Coding Standard field |
adjustment_ring_type |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Adjustment ring height |
MACP Coding Standard field |
adjustment_ring_height |
Double |
|
MANH_DIM |
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Adjustment ring material |
MACP Coding Standard field
The options available in the dropdown list depend on which coding standard is being used. See the Standards and Choice Lists dialog for further information. |
adjustment_ring_material | Text | 50 | 0 | 0 | 0 | 0 | 0 | ||||||||||||||||||||||||||||||||||||||||||||||
Chamber unit length | Length of individual prefabricated manhole or inspection chamber ring units that comprise the manhole or inspection chamber. | chamber_unit_length | Double | MANH_Y | 0 | 9999 | |||||||||||||||||||||||||||||||||||||||||||||||||
Ring condition sound |
MACP Coding Standard field |
ring_condition_sound |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Ring condition broken |
MACP Coding Standard field |
ring_condition_broken |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Ring condition corroded |
MACP Coding Standard field |
ring_condition_corroded |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Ring condition cracked |
MACP Coding Standard field |
ring_condition_cracked |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Ring condition leaking |
MACP Coding Standard field |
ring_condition_leaking |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Ring condition poor install |
MACP Coding Standard field |
ring_condition_poorinstall |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Seal condition sound |
MACP Coding Standard field |
seal_condition_sound |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Seal condition cracked |
MACP Coding Standard field |
seal_condition_cracked |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Seal condition loose |
MACP Coding Standard field |
seal_condition_loose |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Seal condition offset |
MACP Coding Standard field |
seal_condition_offset |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Seal condition missing | MACP Coding Standard field | seal_condition_missing | Boolean | 0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
Frame material |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
frame_material |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Frame bearing surface width |
MACP Coding Standard field |
frame_bearing_surface_width |
Double |
|
MANH_DIM |
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Frame bearing surface depth |
MACP Coding Standard field |
frame_bearing_surface_depth |
Double |
|
MANH_Y |
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Frame depth |
MACP Coding Standard field |
frame_depth |
Double |
|
MANH_Y |
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Frame offset distance |
MACP Coding Standard field |
frame_offset_distance |
Double |
|
MANH_DIM |
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Frame clear open diameter |
MACP Coding Standard field |
frame_clear_open_diam |
Double |
|
MANH_DIM |
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Frame clear open width |
MACP Coding Standard field |
frame_clear_open_width |
Double |
|
MANH_DIM |
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Frame seal inflow |
MACP Coding Standard field |
frame_seal_inflow |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Frame condition sound |
MACP Coding Standard field |
frame_condition_sound |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Frame condition cracked |
MACP Coding Standard field |
frame_condition_cracked |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Frame condition broken |
MACP Coding Standard field |
frame_condition_broken |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Frame condition missing |
MACP Coding Standard field |
frame_condition_missing |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Frame condition corroded |
MACP Coding Standard field |
frame_condition_corroded |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Frame condition coated |
MACP Coding Standard field |
frame_condition_coated |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Shaft access |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
shaft_access |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Shaft depth |
Depth of manhole shaft. |
shaft_depth |
Double |
|
MANH_Y |
0 |
|
|
|
0 |
9999 |
||||||||||||||||||||||||||||||||||||||||||||
Shaft dimension |
Dimension of manhole shaft |
shaft_dim |
Double |
|
MANH_DIM |
0 |
|
|
|
0 |
9999 |
||||||||||||||||||||||||||||||||||||||||||||
Shaft dimension 2 |
Dimension of manhole shaft. |
shaft_dim_2 |
Double |
|
MANH_DIM |
0 |
|
|
|
0 |
9999 |
||||||||||||||||||||||||||||||||||||||||||||
Shaft material |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
shaft_material |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Chimney material 1 |
MACP Coding Standard field The options available in the dropdown list depend on which coding standard is being used for this network. See the Standards and Choice Lists dialog for further information. |
chimney_material1 |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Chimney material 2 |
MACP Coding Standard field The options available in the dropdown list depend on which coding standard is being used for this network. See the Standards and Choice Lists dialog for further information. |
chimney_material2 |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Chimney lining interior |
MACP Coding Standard field |
chimney_lining_interior |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Chimney lining exterior |
MACP Coding Standard field |
chimney_lining_exterior |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Chimney inflow and infiltration |
MACP Coding Standard field |
chimney_ini |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Chimney clear opening |
MACP Coding Standard field |
chimney_clear_opening |
Double |
|
MANH_DIM |
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Chimney depth |
MACP Coding Standard field |
chimney_depth |
Double |
|
MANH_Y |
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Chamber construction |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
chamber_construction |
Text |
10 |
|
1 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Chamber dimension |
Dimension of manhole chamber. |
chamber_dim |
Double |
|
MANH_DIM |
0 |
|
|
|
0 |
9999 |
||||||||||||||||||||||||||||||||||||||||||||
Chamber dimension 2 |
Dimension of manhole chamber. |
chamber_dim_2 |
Double |
|
MANH_DIM |
0 |
|
|
|
0 |
9999 |
||||||||||||||||||||||||||||||||||||||||||||
Chamber floor depth from cover |
Distance between chamber floor and manhole cover level. |
chamber_floor_depth |
Double |
|
MANH_Y |
0 |
|
|
|
0 |
9999 |
||||||||||||||||||||||||||||||||||||||||||||
Chamber shape |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
chamber_shape |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Soffit type |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
soffit_type |
Text |
10 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Cone type |
MACP Coding Standard field The options available in the dropdown list depend on which coding standard is being used for this network. See the Standards and Choice Lists dialog for further information. |
cone_type |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cone material |
MACP Coding Standard field The options available in the dropdown list depend on which coding standard is being used for this network. See the Standards and Choice Lists dialog for further information. |
cone_material |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cone depth |
MACP Coding Standard field |
cone_depth |
Double |
|
MANH_Y |
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cone lining interior |
MACP Coding Standard field |
cone_lining_interior |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Cone lining exterior |
MACP Coding Standard field |
cone_lining_exterior |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Wall diameter |
MACP Coding Standard field |
wall_diam |
Double |
|
MANH_DIM |
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Wall depth |
MACP Coding Standard field |
wall_depth |
Double |
|
MANH_Y |
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Wall by size |
MACP Coding Standard field |
wall_bysize |
Double |
|
MANH_DIM |
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Wall material |
MACP Coding Standard field The options available in the dropdown list depend on which coding standard is being used for this network. See the Standards and Choice Lists dialog for further information. |
wall_material |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Wall lining interior |
MACP Coding Standard field The options available in the dropdown list depend on which coding standard is being used for this network. See the Standards and Choice Lists dialog for further information. |
wall_lining_interior |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Wall lining exterior |
MACP Coding Standard field The options available in the dropdown list depend on which coding standard is being used for this network. See the Standards and Choice Lists dialog for further information. |
wall_lining_exterior |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Number of steps |
Number of steps installed in manhole. |
num_steps |
Integer |
|
|
0 |
|
|
|
0 |
99 |
||||||||||||||||||||||||||||||||||||||||||||
Number of ladders |
Number of ladders installed in manhole. |
num_ladders |
Integer |
|
|
0 |
|
|
|
0 |
9 |
||||||||||||||||||||||||||||||||||||||||||||
Number of landings |
Number of landings installed in manhole. |
num_landings |
Long Integer |
|
|
0 |
|
|
|
0 |
9 |
||||||||||||||||||||||||||||||||||||||||||||
Number of regulating courses |
|
num_regulating |
Integer |
|
|
0 |
|
|
|
0 |
9 |
||||||||||||||||||||||||||||||||||||||||||||
Step material |
MACP Coding Standard field The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
step_material |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Rim to invert |
MACP Coding Standard field Distance from rim to invert of upstream manhole. |
rim_to_invert |
Double |
|
MANH_DIM |
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Grade to invert |
MACP Coding Standard field Distance or from average grade to invert of outgoing invert. |
grade_to_invert |
Double |
|
MANH_DIM |
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Rim to grade |
MACP Coding Standard field Distance or from rim to average grade of outgoing invert. |
rim_to_grade |
Double |
|
MANH_DIM |
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Channel installed |
MACP Coding Standard field |
channel_installed |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Channel material |
MACP Coding Standard field |
channel_material |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Channel type |
MACP Coding Standard field The options available in the dropdown list depend on which coding standard is being used for this network. See the Standards and Choice Lists dialog for further information. |
channel_type |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Channel exposure |
MACP Coding Standard field The options available in the dropdown list depend on which coding standard is being used for this network. See the Standards and Choice Lists dialog for further information. |
channel_exposure |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Bench present |
MACP Coding Standard field The options available in the dropdown list depend on which coding standard is being used for this network. See the Standards and Choice Lists dialog for further information. |
bench_present |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Bench material |
MACP Coding Standard field The options available in the dropdown list depend on which coding standard is being used for this network. See the Standards and Choice Lists dialog for further information. |
bench_material |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Bench lining |
MACP Coding Standard field The options available in the dropdown list depend on which coding standard is being used for this network. See the Standards and Choice Lists dialog for further information. |
bench_lining |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Leveler material |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
leveler_material |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Inlet type |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
manhole_inlet_type | Text | 30 | |||||||||||||||||||||||||||||||||||||||||||||||||||
Clear opening area | Clear area of grate or opening. | clear_opening | Double | NA | 3 | ||||||||||||||||||||||||||||||||||||||||||||||||||
Cross slope | Rate of change of roadway elevation with respect to distance perpendicular to the direction of travel. Also known as transverse slope. | cross_slope | Double | S | 3 | ||||||||||||||||||||||||||||||||||||||||||||||||||
% clogging | Factor used to model the effect of clogging from debris. | debris | Double | 0 | |||||||||||||||||||||||||||||||||||||||||||||||||||
Grate length | Grate dimension. | grate_length | Double | L | 3 | ||||||||||||||||||||||||||||||||||||||||||||||||||
Grate width | Grate dimension. | grate_width | Double | L | 3 | ||||||||||||||||||||||||||||||||||||||||||||||||||
Gutter depression | Depth of gutter depression for a depressed inlet. | gutter_depression | Double | L | 3 | ||||||||||||||||||||||||||||||||||||||||||||||||||
Lateral depression | Lateral width of gutter depression for a depressed inlet. | lateral_depression | Double | L | 3 | ||||||||||||||||||||||||||||||||||||||||||||||||||
Opening height | Height of curb opening. | opening_height | Double | L | 3 | ||||||||||||||||||||||||||||||||||||||||||||||||||
Opening length | Length of curb opening. | opening_length | Double | L | 3 | ||||||||||||||||||||||||||||||||||||||||||||||||||
Surface type asphalt |
MACP Coding Standard field |
surface_type_asphalt |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Surface type concrete pavement |
MACP Coding Standard field |
surface_type_concretepavement |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Surface type concrete collar |
MACP Coding Standard field |
surface_type_concretecollar |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Surface type grass dirt |
MACP Coding Standard field |
surface_type_grassdirt |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Surface type gravel |
MACP Coding Standard field |
surface_type_gravel |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Surface type other |
MACP Coding Standard field |
surface_type_other |
Boolean |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Potential for runoff |
MACP Coding Standard field Type of flow restriction used. The options available in the dropdown list depend on which coding standard is being used for this network. See the Standards and Choice Lists dialog for further information. |
potential_for_runoff |
Text |
50 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Access action |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
access_action |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Access time |
The options available in the dropdown list depend on the choices defined in the Standards and Choice Lists dialog. |
access_time |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Main comment |
Comment on condition of manhole. |
main_comment |
Text |
40 |
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Installation cost |
The original installation cost of the asset. This generally includes all costs incurred (e.g. mantime, asset purchase costs etc). This information is used in depreciation reports. |
install_cost |
Double |
|
WN_COST |
2 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Rehabilitation cost |
Rehabilitation costs to be incurred in bringing the asset to an acceptable condition. This is used in rehabilitation reports. |
rehab_cost |
Double |
|
WN_COST |
2 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Inspection cost |
Estimated cost of asset inspection. |
inspection_cost |
Double |
|
WN_COST |
2 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Replacement cost |
The estimated cost for completely replacing an asset. |
replace_cost |
Double |
|
WN_COST |
2 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Expected lifetime |
The expected lifetime of the asset. This is used in depreciation reports as the period over which installation costs may be depreciated. |
lifetime |
Long Integer |
|
|
0 |
|
|
|
|
999 |
||||||||||||||||||||||||||||||||||||||||||||
Current value |
Current value of the asset. This gives an indication of depreciation costs as depreciation cost = installation cost - current value. |
current_value |
Double |
|
WN_COST |
2 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
Lateral US node ID |
Reference ID of upstream node of pipe to which node is laterally connected. |
lat_us_node_id |
Text |
40 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Lateral DS node ID |
Reference ID of downstream node of pipe to which node is laterally connected. |
lat_ds_node_id |
Text |
40 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Lateral link suffix |
Link suffix of pipe to which node is laterally connected. |
lat_link_suffix |
Text |
1 |
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Lateral channel ID | ID of channel to which node is laterally connected. | lat_channel_id | Text | 40 | 0 | 0 | 0 | 0 | 0 | ||||||||||||||||||||||||||||||||||||||||||||||
Lateral distance from US node |
The distance along a pipe from the start node of the pipe to the location of the lateral (hydrant, fitting etc.). |
lat_distance |
Double |
|
L |
2 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Lateral circumferential location |
Clock reference of position of node on pipe to which node is laterally connected. |
lat_circ_location |
Integer |
|
|
0 |
|
0 |
0 |
0 |
0 |
||||||||||||||||||||||||||||||||||||||||||||
Name groups | Click the button to display the Name Groups Editor, used to view and edit the Asset Name Groups to which the object belongs. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Attachments |
Click the button to display the Attachments Editor, used to attach and manage photos, sketches and other files associated with the network object. See Attachments Editor and Common Data Fields for further details. |
attachments | Array | ||||||||||||||||||||||||||||||||||||||||||||||||||||
Has photos |
Check box indicating whether photos are associated with the node. |
has_photos |
Boolean |
|
|
0 |
|
|
|
|
|
||||||||||||||||||||||||||||||||||||||||||||
General properties data fields | See Common Data Fields for details of field in the General properties section of the property sheet. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
User defined properties data fields | See Common Data Fields - User Fields for details of fields in the User defined properties section of the property sheet. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
Time series links |
Click the button to display the Time Series Data Source Grid, which is used to specify or update the time series data streams that are linked to this node. |
tsdb_links |